Medical physics challenges in clinical MR-guided radiotherapy
The integration of magnetic resonance imaging (MRI) for guidance in external beam
radiotherapy has faced significant research and development efforts in recent years. The …
radiotherapy has faced significant research and development efforts in recent years. The …
Machine QA for the Elekta Unity system: a report from the Elekta MR‐linac consortium
DA Roberts, C Sandin, PT Vesanen, H Lee… - Medical …, 2021 - Wiley Online Library
Over the last few years, magnetic resonance image‐guided radiotherapy systems have
been introduced into the clinic, allowing for daily online plan adaption. While quality …
been introduced into the clinic, allowing for daily online plan adaption. While quality …
[图书][B] Monte Carlo techniques in radiation therapy
J Seco, F Verhaegen - 2013 - api.taylorfrancis.com
Monte Carlo simulation techniques made a slow entry in the field of radiotherapy in the late
1970s. Since then they have gained enormous popularity, judging by the number of papers …
1970s. Since then they have gained enormous popularity, judging by the number of papers …
A deep learning approach to generate synthetic CT in low field MR-guided radiotherapy for lung cases
J Lenkowicz, C Votta, M Nardini, F Quaranta… - Radiotherapy and …, 2022 - Elsevier
Introduction This study aims to apply a conditional Generative Adversarial Network (cGAN)
to generate synthetic Computed Tomography (sCT) from 0.35 Tesla Magnetic Resonance …
to generate synthetic Computed Tomography (sCT) from 0.35 Tesla Magnetic Resonance …
Time analysis of online adaptive magnetic resonance–guided radiation therapy workflow according to anatomical sites
G Güngör, İ Serbez, B Temur, G Gür, N Kayalılar… - Practical radiation …, 2021 - Elsevier
Purpose To document time analysis of detailed workflow steps for the online adaptive
magnetic resonance–guided radiation therapy treatments (MRgRT) with the ViewRay …
magnetic resonance–guided radiation therapy treatments (MRgRT) with the ViewRay …
ICRU REPORT 97: MRI-guided radiation therapy using MRI-linear accelerators
The International Commission on Radiation Units and Measurements (ICRU), since its
inception in 1925, has had as its principal objective the development of internationally …
inception in 1925, has had as its principal objective the development of internationally …
Relative dosimetry with an MR‐linac: response of ion chambers, diamond, and diode detectors for off‐axis, depth dose, and output factor measurements
DJ O'Brien, J Dolan, S Pencea, N Schupp… - Medical …, 2018 - Wiley Online Library
Purpose The purpose of this study was to acquire beam data for an MR‐linac, with and
without a 1.5 T magnetic field, by using a variety of commercially available detectors to …
without a 1.5 T magnetic field, by using a variety of commercially available detectors to …
Millisecond speed deep learning based proton dose calculation with Monte Carlo accuracy
O Pastor-Serrano, Z Perkó - Physics in Medicine & Biology, 2022 - iopscience.iop.org
Objective. Next generation online and real-time adaptive radiotherapy workflows require
precise particle transport simulations in sub-second times, which is unfeasible with current …
precise particle transport simulations in sub-second times, which is unfeasible with current …
Magnetic field induced dose effects in radiation therapy using MR‐linacs
MR‐guided radiotherapy (MRgRT) is one of the most significant advances in radiotherapy in
recent years. The hybrid systems were designed to visualize patient anatomical and …
recent years. The hybrid systems were designed to visualize patient anatomical and …
Development and evaluation of a GEANT4‐based Monte Carlo Model of a 0.35 T MR‐guided radiation therapy (MRgRT) linear accelerator
AU Khan, EA Simiele, R Lotey, LA DeWerd… - Medical …, 2021 - Wiley Online Library
Purpose The aim of this work was to develop and benchmark a magnetic resonance (MR)‐
guided linear accelerator head model using the GEANT4 Monte Carlo (MC) code. The …
guided linear accelerator head model using the GEANT4 Monte Carlo (MC) code. The …