Experimentally Consistent Simulation of Aβ21–30 Peptides with a Minimal NMR Bias

DB Amirkulova, M Chakraborty… - The Journal of Physical …, 2020 - ACS Publications
Misfolded amyloid peptides are neurotoxic molecules associated with Alzheimer's disease.
The Aβ21–30 peptide fragment is a decapeptide fragment of the complete Aβ42 peptide …

Effect of brine injection on water dynamics in postmortem muscle: study of T2 and diffusion coefficients by MR microscopy

L Foucat, S Benderbous, G Bielicki, M Zanca… - Magnetic Resonance …, 1995 - Elsevier
The dynamics of water in postmortem muscle were studied by magnetic resonance
microscopy (MRM). Rabbit muscles were arterially injected with 3 and 5 M NaCl brine. T2 …

Measurement of one-dimensional spatially resolved self-diffusion coefficients and longitudinal relaxation times with a single b1 gradient

E Mischler, F Humbert, B Diter, D Canet - Journal of Magnetic Resonance …, 1995 - Elsevier
A very simple experimental setup, involving a single coil for generating a radiofrequency
field gradient, enables one to determine the self-diffusion coefficient and the longitudinal …

Small animal neuroimaging using magnetic resonance microscopy

ET Ahrens, PT Narasimhan, T Nakada… - Progress in Nuclear …, 2002 - Elsevier
Magnetic resonance imaging (MRI) provides threedimensional (3D) non-invasive views into
optically opaque tissues with exquisite sensitivity to the local physical and chemical …

A Signal Peak Separation Index for axisymmetric B-tensor encoding

G Rensonnet, J Rafael-Patiño, B Macq… - … MICCAI Workshop, Lima …, 2021 - Springer
Abstract Diffusion-weighted MRI (DW-MRI) has recently seen a rising interest in planar,
spherical and general B-tensor encodings. Some of these sequences have aided traditional …

Effects of, and corrections for, cross‐term interactions in q‐space MRI

O Brihuega‐Moreno, FP Heese… - … in Medicine: An …, 2004 - Wiley Online Library
The present study assesses the effects of cross‐term interactions between diffusion and
imaging gradients in magnetic resonance imaging q‐space analysis, and corrects for those …

Manifestation and post hoc correction of gradient cross-term artifacts in DTI

G Nair, XP Hu - Magnetic Resonance Imaging, 2012 - Elsevier
Cross-terms between imaging and diffusion gradients, unaccounted for during tensor
calculations, can lead to erroneous estimation of diffusivity and fractional anisotropy (FA) in …

Basis for the application of analytical models of the Bloch NMR flow equations for functional magnetic resonance imaging (fMRI): A review

OB Awojoyogbe, M Dada - Recent Patents on Medical Imaging …, 2011 - ingentaconnect.com
Nuclear magnetic resonance (NMR) is widely used in physics, chemistry, biology,
engineering and medicine because there is hardly another technique that is so informative …

Stimulated echoes and spin echoes. Simultaneous determination of T2, diffusion coefficient, and RF homogeneity

CJR Counsell - Journal of Magnetic Resonance, Series B, 1993 - Elsevier
By comparing information encoded in multiple signals it is possible to measure several
sample-dependent parameters in a single experiment with the advantages that the …

Potential in reducing scan times of HARDI by accurate correction of the cross‐term in a hemispherical encoding scheme

KH Cho, CH Yeh, YP Chao, JJ Wang… - Journal of Magnetic …, 2009 - Wiley Online Library
Purpose To reduce the scan time of high angular resolution diffusion imaging (HARDI) by
using the hemispherical encoding scheme with the cross‐term correction. Materials and …