Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning

IJ Chetty, B Curran, JE Cygler, JJ DeMarco… - Medical …, 2007 - Wiley Online Library
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …

Fifty years of Monte Carlo simulations for medical physics

DWO Rogers - Physics in Medicine & Biology, 2006 - iopscience.iop.org
Monte Carlo techniques have become ubiquitous in medical physics over the last 50 years
with a doubling of papers on the subject every 5 years between the first PMB paper in 1967 …

Online magnetic resonance image guided adaptive radiation therapy: first clinical applications

S Acharya, BW Fischer-Valuck, R Kashani… - International Journal of …, 2016 - Elsevier
Purpose To demonstrate the feasibility of online adaptive magnetic resonance (MR) image
guided radiation therapy (MR-IGRT) through reporting of our initial clinical experience and …

[PDF][PDF] PENELOPE-2014: A code system for Monte Carlo simulation of electron and photon transport

D Bank - 2015 - oecd-nea.org
The computer code system penelope (version 2014) performs Monte Carlo simulation of
coupled electron-photon transport in arbitrary materials for a wide energy range, from a few …

[HTML][HTML] Clinical implementation of magnetic resonance imaging guided adaptive radiotherapy for localized prostate cancer

SU Tetar, AME Bruynzeel, FJ Lagerwaard… - Physics and imaging in …, 2019 - Elsevier
Background and purpose Magnetic resonance-guided radiation therapy (MRgRT) has
recently become available in clinical practice and is expected to expand significantly in …

[图书][B] Monte Carlo techniques in radiation therapy

J Seco, F Verhaegen - 2013 - api.taylorfrancis.com
Monte Carlo simulation techniques made a slow entry in the field of radiotherapy in the late
1970s. Since then they have gained enormous popularity, judging by the number of papers …

[PDF][PDF] The EGS5 code system

H Hirayama, Y Namito, WR Nelson, AF Bielajew… - 2005 - rcwww.kek.jp
In the nineteen years since EGS4 was released, it has been used in a wide variety of
applications, particularly in medical physics, radiation measurement studies, and industrial …

Intensity-modulated radiotherapy: current status and issues of interest

Intensity Modulated Radiation Therapy … - International Journal of …, 2001 - Elsevier
Purpose. To develop and disseminate a report aimed primarily at practicing radiation
oncology physicians and medical physicists that describes the current state-of-the-art of …

A PENELOPE‐based system for the automated Monte Carlo simulation of clinacs and voxelized geometries—application to far‐from‐axis fields

J Sempau, A Badal, L Brualla - Medical physics, 2011 - Wiley Online Library
Purpose: Two new codes, penEasy and penEasyLinac, which automate the Monte Carlo
simulation of Varian Clinacs of the 600, 1800, 2100, and 2300 series, together with their …

Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams

ON Vassiliev, TA Wareing, J McGhee… - Physics in Medicine …, 2010 - iopscience.iop.org
A new grid-based Boltzmann equation solver, Acuros™, was developed specifically for
performing accurate and rapid radiotherapy dose calculations. In this study we …