2018 AATS/ACC/SCAI/STS expert consensus systems of care document: operator and institutional recommendations and requirements for transcatheter aortic valve …

JE Bavaria, CL Tommaso, RG Brindis, JD Carroll… - Journal of the American …, 2019 - jacc.org
Registry data that shows a clinically meaningful association of higher mortality and other
major complications with site annual volume below the recommended threshold of 50 …

Valve in valve transcatheter aortic valve implantation (ViV‐TAVI) versus redo—surgical aortic valve replacement (redo‐SAVR): A systematic review and meta‐analysis

N Nalluri, V Atti, AB Munir, B Karam… - Journal of …, 2018 - Wiley Online Library
Background Bioprosthetic (BP) valves have been increasingly used for aortic valve
replacement over the last decade. Due to their limited durability, patients presenting with …

Valve-in-valve transcatheter aortic valve replacement versus redo surgical aortic valve replacement: an updated meta-analysis

MPBO Sá, J Van den Eynde, M Simonato… - Cardiovascular …, 2021 - jacc.org
Objectives The aim of this study was to evaluate early results of valve-in-valve (ViV)
transcatheter aortic valve replacement (TAVR) versus redo surgical aortic valve replacement …

Transcatheter ViV versus redo surgical AVR for the management of failed biological prosthesis: early and late outcomes in a propensity-matched cohort

DY Tam, C Dharma, RV Rocha, M Ouzounian… - Cardiovascular …, 2020 - jacc.org
Objectives The aim of this study was to compare early and late outcomes between redo
surgical aortic valve replacement (AVR) and valve-in-valve (ViV) transcatheter AVR …

Postoperative delirium after transcatheter aortic valve replacement: An updated systematic review and meta‐analysis

X Ma, H Chu, K Han, Q Shao, Y Yu, S Jia… - Journal of the …, 2023 - Wiley Online Library
Aims To perform an updated systematic review and meta‐analysis of postoperative delirium
(POD) after transcatheter aortic valve replacement (TAVR). Methods We conducted a …

Transcatheter valve‐in‐valve versus redo surgical aortic valve replacement for the treatment of degenerated bioprosthetic aortic valve: a systematic review and meta …

DY Tam, TX Vo, HC Wijeysundera… - Catheterization and …, 2018 - Wiley Online Library
Objective To determine the safety and efficacy of valve‐in‐valve transcatheter aortic valve
replacement (ViV) versus redo surgical aortic valve replacement (SAVR) for the treatment of …

Valve‐in‐Valve Transcatheter Aortic Valve Replacement Versus Redo Surgical Aortic Valve Replacement for Failed Surgical Aortic Bioprostheses: A Systematic …

M Raschpichler, S de Waha, D Holzhey… - Journal of the …, 2022 - Am Heart Assoc
Background In the absence of randomized controlled trials, reports from nonrandomized
studies comparing valve‐in‐valve implantation (ViV) to redo surgical aortic valve …

Comparative performance of transcatheter aortic valve-in-valve implantation versus conventional surgical redo aortic valve replacement in patients with degenerated …

M Gozdek, GM Raffa, P Suwalski… - European Journal of …, 2018 - academic.oup.com
The objective of this report was to directly compare, by means of a systematic review and
meta-analysis, redo surgical aortic valve replacement (re-sAVR) with valve-in-valve …

Meta-analysis of valve-in-valve transcatheter aortic valve implantation versus redo-surgical aortic valve replacement in failed bioprosthetic aortic valve

A Al-Abcha, Y Saleh, M Boumegouas, R Prasad… - The American Journal of …, 2021 - Elsevier
This meta-analysis was conducted to compare clinical outcomes of valve-in-valve
transcatheter aortic valve implantation (ViV-TAVI) versus redo-surgical aortic valve …

Meta-analysis of transcatheter valve-in-valve implantation versus redo aortic valve surgery for bioprosthetic aortic valve dysfunction

S Neupane, H Singh, J Lämmer, H Othman… - The American Journal of …, 2018 - Elsevier
Transcatheter valve-in-valve implantation (ViV-TAVI) has evolved as an alternative to redo
surgical valve replacement (redo-SAVR) for high-risk patients with aortic bioprosthetic valve …