Catheter interventions for hemodialysis fistulas and grafts

JA Bittl - JACC: Cardiovascular Interventions, 2010 - jacc.org
More than 1 in 1,000 patients in the US has end-stage renal disease, and most patients who
require renal-replacement therapy undergo hemodialysis. By the year 2020, more than …

Reporting standards for percutaneous interventions in dialysis access

RJ Gray, S Chair, D Sacks, LG Martin… - Journal of vascular and …, 1999 - Elsevier
Reporting Standards for Percutaneous Interventions in Dialysis ~ ccess ' Page 1 Reporting
Standards for Percutaneous Interventions in Dialysis ~ ccess ' Richard J. Gray, MD Subcommittee …

Paclitaxel-coated balloon angioplasty vs. plain balloon dilation for the treatment of failing dialysis access: 6-month interim results from a prospective randomized …

K Katsanos, D Karnabatidis, P Kitrou… - Journal of …, 2012 - journals.sagepub.com
Purpose To report the 6-month results of a prospective randomized trial investigating
angioplasty with paclitaxel-coated balloons (PCB) vs. plain balloon angioplasty (BA) for the …

Detection and treatment of dysfunctional hemodialysis access grafts: effect of a surveillance program on graft patency and the incidence of thrombosis.

AA Safa, K Valji, AC Roberts, TW Ziegler, RJ Hye… - Radiology, 1996 - pubs.rsna.org
PURPOSE: To determine the value of a hemodialysis graft surveillance program in reducing
the incidence of graft thrombosis and prolonging graft patency by means of early detection …

[HTML][HTML] Effectiveness and safety of dialysis vascular access procedures performed by interventional nephrologists

GA Beathard, T Litchfield, POFORMS Lifeline - Kidney international, 2004 - Elsevier
Effectiveness and safety of dialysis vascular access procedures performed by interventional
nephrologists. Background The purpose of this report was to analyze the results obtained …

Quality improvement guidelines for percutaneous management of the thrombosed or dysfunctional dialysis access

JE Aruny, CA Lewis, JF Cardella, PE Cole… - Journal of vascular and …, 1999 - Elsevier
John E. Aruny, MD Curtis A. Lewis, MD John F. Cardella, MD Patricia E. Cole, PhD, MD
Andrew Davis, MD Alain T. Drooz, MD Clement J. Grassi, MD Richard J. Gray, MD James W …

Apparatus and methods for preventing or treating failure of hemodialysis vascular access and other vascular grafts

SS Iyer, NN Kipshidze, VV Nikolaychik - US Patent 6,726,923, 2004 - Google Patents
US6726923B2 - Apparatus and methods for preventing or treating failure of hemodialysis
vascular access and other vascular grafts - Google Patents US6726923B2 - Apparatus and …

A metaanalysis comparing surgical thrombectomy, mechanical thrombectomy, and pharmacomechanical thrombolysis for thrombosed dialysis grafts

LD Green, DS Lee, DS Kucey - Journal of vascular surgery, 2002 - Elsevier
Background: The achievement and maintenance of access sites for hemodialysis is a
persistent challenge for both the vascular surgeon and the clinical nephrologist. The advent …

Quality improvement guidelines for percutaneous management of the thrombosed or dysfunctional dialysis access

JE Aruny, CA Lewis, JF Cardella, PE Cole… - Journal of vascular and …, 2003 - infona.pl
Quality Improvement Guidelines for Percutaneous Management of the Thrombosed or
Dysfunctional Dialysis Access × Close The Infona portal uses cookies, ie strings of text saved …

Comparison of SMART stent placement for arteriovenous graft salvage versus successful graft PTA

PM Vogel, C Parise - Journal of vascular and interventional radiology, 2005 - Elsevier
PURPOSE: To compare the SMART (shape memory alloy recoverable technology) stent
with percutaneous transluminal angioplasty (PTA) alone in hemodialysis access venous …