A review on radiochromic film dosimetry for dose verification in high energy photon beams
T Santos, T Ventura, M do Carmo Lopes - Radiation Physics and Chemistry, 2021 - Elsevier
A dosimetry system composed by Gafchromic™ EBT films and a flatbed document scanner
is a valuable tool for patient-specific quality assurance (QA) of complex external beam …
is a valuable tool for patient-specific quality assurance (QA) of complex external beam …
Small-field radiotherapy photon beam output evaluation: Detectors reviewed
Small fields (few cm and below) are being applied in therapy independently or as mm/sub-
cm segments of larger fields. Included are intensity modulated radiotherapy …
cm segments of larger fields. Included are intensity modulated radiotherapy …
Linac-based radiosurgery for multiple brain metastases: comparison between two mono-isocenter techniques with multiple non-coplanar arcs
R Ruggieri, S Naccarato, R Mazzola, F Ricchetti… - Radiotherapy and …, 2019 - Elsevier
Background and purpose Three mono-isocenter techniques with multiple non-coplanar arcs
are nowadays clinically available for linac-based stereotactic radiosurgery (SRS) of multiple …
are nowadays clinically available for linac-based stereotactic radiosurgery (SRS) of multiple …
Experimental verification the electron return effect around spherical air cavities for the MR‐Linac using Monte Carlo calculation
Purpose Dose deposition around unplanned air cavities during magnetic resonance‐guided
radiotherapy (MRgRT) is influenced by the electron return effect (ERE). This is clinically …
radiotherapy (MRgRT) is influenced by the electron return effect (ERE). This is clinically …
Energy dependence of the Gafchromic EBT4 film: Dose‐response curves for 70 kV, 6 MV, 6 MV FFF, 10 MV FFF, and 15 MV x‐ray beams
Background EBT4 was newly released for radiotherapy quality assurance to improve the
signal‐to‐noise ratio in radiochromic film dosimetry. It is important to know its dose …
signal‐to‐noise ratio in radiochromic film dosimetry. It is important to know its dose …
[HTML][HTML] Characterisation of a synthetic diamond detector for end-to-end dosimetry in stereotactic body radiotherapy and radiosurgery
M Shaw, J Lye, A Alves, S Keehan, J Lehmann… - Physics and Imaging in …, 2021 - Elsevier
Background and purpose Synthetic diamond detectors offer real time measurement of dose
in radiotherapy applications which require high spatial resolution. Additional considerations …
in radiotherapy applications which require high spatial resolution. Additional considerations …
[HTML][HTML] A multi-point optical fibre sensor for proton therapy
C Penner, S Usherovich, S Andru… - Electronics, 2024 - mdpi.com
As the technology to deliver precise and very high radiotherapeutic doses with narrow
margins grows to better serve patients with complex radiotherapeutic needs, so does the …
margins grows to better serve patients with complex radiotherapeutic needs, so does the …
Performance characterization of a novel hybrid dosimetry insert for simultaneous spatial, temporal, and motion‐included dosimetry for MR‐linac
P Uijtewaal, P Borman, B Cote, Y LeChasseur… - Medical …, 2024 - Wiley Online Library
Background Several (online) adaptive radiotherapy procedures are available to maximize
healthy tissue sparing in the presence of inter/intrafractional motion during stereotactic body …
healthy tissue sparing in the presence of inter/intrafractional motion during stereotactic body …
[HTML][HTML] Clinical utility of Gafchromic film in an MRI-guided linear accelerator
I Xhaferllari, JP Kim, R Liyanage, C Liu, D Du… - Radiation …, 2021 - Springer
Background The purpose of this study is to comprehensively evaluate the suitability of
Gafchromic EBT3 and EBT-XD film for dosimetric quality assurance in 0.35 T MR-guided …
Gafchromic EBT3 and EBT-XD film for dosimetric quality assurance in 0.35 T MR-guided …
The irregular breathing effect on target volume and coverage for lung stereotactic body radiotherapy
CH Pan, AC Shiau, KC Li, SH Hsu… - Journal of applied …, 2019 - Wiley Online Library
The major challenge in treating a mobile target is obtaining the temporal and spatial
information imaging and treatment details. This phantom study quantitatively evaluates the …
information imaging and treatment details. This phantom study quantitatively evaluates the …