Robust nonadiabatic T2 preparation using universal parallel‐transmit kT‐point pulses for 3D FLAIR imaging at 7 T
V Gras, ED Pracht, F Mauconduit… - Magnetic resonance …, 2019 - Wiley Online Library
Purpose The fluid attenuated inversion recovery sequence is a pillar technique to detect
brain lesions in MRI. At ultrahigh field, the lengthening of T1 often advocates a T2‐weighting …
brain lesions in MRI. At ultrahigh field, the lengthening of T1 often advocates a T2‐weighting …
A pathway towards a two‐dimensional, bore‐mounted, volume body coil concept for ultra high‐field magnetic resonance imaging
Lack of a body‐sized, bore‐mounted, radiofrequency (RF) body coil for ultrahigh field (UHF)
magnetic resonance imaging (MRI) is one of the major drawbacks of UHF, hampering the …
magnetic resonance imaging (MRI) is one of the major drawbacks of UHF, hampering the …
Flexible metasurface for improving brain imaging at 7T
Purpose Ultra‐high field MRI offers unprecedented detail for noninvasive visualization of the
human brain. However, brain imaging is challenging at 7T due to the B 1+ _1^+ field …
human brain. However, brain imaging is challenging at 7T due to the B 1+ _1^+ field …
Clinical applications of ultra-high field magnetic resonance imaging in multiple sclerosis
M Inglese, L Fleysher, N Oesingmann… - Expert review of …, 2018 - Taylor & Francis
Introduction: Magnetic resonance imaging (MRI) is of paramount importance for the early
diagnosis of multiple sclerosis (MS) and MRI findings are part of the MS diagnostic criteria …
diagnosis of multiple sclerosis (MS) and MRI findings are part of the MS diagnostic criteria …
Seven-tesla MRI of hippocampal sclerosis: an in vivo feasibility study with histological correlations
H Stefanits, E Springer, E Pataraia… - Investigative …, 2017 - journals.lww.com
Methods High-resolution, T2-weighted FSE MRI in 14 patients with drug-resistant temporal
lobe epilepsy was performed on a 7 T Magnetom using a 32-channel coil. Four independent …
lobe epilepsy was performed on a 7 T Magnetom using a 32-channel coil. Four independent …
Image artifact management for clinical magnetic resonance imaging on a 7 T scanner using single-channel radiofrequency transmit mode
Objectives The aim of this work was to devise mitigation strategies for addressing a range of
image artifacts on a clinical 7 T magnetic resonance imaging scanner using the regulatory …
image artifacts on a clinical 7 T magnetic resonance imaging scanner using the regulatory …
[HTML][HTML] The pulvinar nucleus and antidepressant treatment: dynamic modeling of antidepressant response and remission with ultra-high field functional MRI
C Kraus, M Klöbl, M Tik, B Auer, T Vanicek… - Molecular …, 2019 - nature.com
Functional magnetic resonance imaging (fMRI) successfully disentangled neuronal
pathophysiology of major depression (MD), but only a few fMRI studies have investigated …
pathophysiology of major depression (MD), but only a few fMRI studies have investigated …
[HTML][HTML] Neurophysiological effects of whole coffee cherry extract in older adults with subjective cognitive impairment: a randomized, double-blind, placebo-controlled …
Bioactive plant-based compounds have shown promise as protective agents across multiple
domains including improvements in neurological and psychological measures …
domains including improvements in neurological and psychological measures …
Hippocampal subfields and thalamic nuclei associations with clinical outcomes in multiple sclerosis: An ultrahigh field MRI study
Background Previous studies have shown that thalamic and hippocampal
neurodegeneration is associated with clinical decline in Multiple Sclerosis (MS). However …
neurodegeneration is associated with clinical decline in Multiple Sclerosis (MS). However …
Fractal analysis of MRI data at 7 T: how much complex is the cerebral cortex?
C Marzi, M Giannelli, C Tessa, M Mascalchi… - IEEE …, 2021 - ieeexplore.ieee.org
The human brain is a highly complex structure, which can be only partially described by
conventional metrics derived from magnetic resonance imaging (MRI), such as volume …
conventional metrics derived from magnetic resonance imaging (MRI), such as volume …