Low-dose dental computed tomography: significant dose reduction without loss of image quality

P Rustemeyer, U Streubühr, J Suttmoeller - Acta radiologica, 2004 - Taylor & Francis
Purpose: To measure and reduce the patient dose during computed tomography (CT) for
dental applications. Material and Methods: Lithium fluoride thermoluminescent dosimeters …

[HTML][HTML] Monte Carlo calculation of organ and effective doses due to photon and neutron point sources and typical X-ray examinations: results of an international …

C Huet, J Eakins, M Zankl, JM Gómez-Ros… - Radiation …, 2022 - Elsevier
This paper summarizes the results of an intercomparison on the use of the ICRP Reference
Computational Phantoms with radiation transport codes, which was organized by …

ICRP Publication 144: Dose Coefficients for External Exposures to Environmental Sources

N Petoussi-Henß, D Satoh, A Endo… - Annals of the …, 2020 - journals.sagepub.com
This publication presents radionuclide-specific organ and effective dose-rate coefficients for
members of the public resulting from environmental external exposures to radionuclide …

[HTML][HTML] Monte Carlo calculation of organ dose coefficients for internal dosimetry: Results of an international intercomparison exercise

M Zankl, JMG Ros, M Moraleda, U Reichelt… - Radiation …, 2021 - Elsevier
EURADOS Working Group 6 has organized an intercomparison exercise on the use of the
ICRP Reference Computational Phantoms with radiation transport codes. This paper …

Experimental validation of Monte Carlo calculations with a voxelized Rando–Alderson phantom: a study on influence parameters

L Struelens, F Vanhavere… - Physics in Medicine & …, 2008 - iopscience.iop.org
The development and improvement of techniques for an accurate dose assessment in
medical physics is an important task. In this study, we focus on the validation of Monte Carlo …

Automatic organ completion with image stitching for personalized radiation dosimetry in CT examinations

L Xin, W Zhuo, H Liu, T Xie - Medical Physics, 2023 - Wiley Online Library
Purpose Computed tomography (CT) image‐based patient‐specific voxel‐based dosimetry
has difficulties complementing missing tissues for organs located partially inside or …

Comparison of point, line and volume dose calculations for exposure to nuclear medicine therapy patients

AB de Carvalho Jr, MG Stabin, JA Siegel, J Hunt - Health Physics, 2011 - journals.lww.com
This work compared the predicted dose to an individual due to exposure from a radioactive
patient using three models (point, line, and volume), for three therapeutic regimens …

A comparative study between MC simulation and TLD measurements of radiation doses to other parts of the body during gynaecological brachytherapy

CO Doudoo, PK Gyekye, G Emi-Reynolds… - Health and …, 2024 - Springer
Purpose The study of long-term radiation effects has become important due to the growing
survival rates among cancer patients. Brachytherapy treatment planning systems do not …

Dose conversion coefficients for ICRP110 voxel phantom in the Geant4 Monte Carlo code

MC Martins, TPV Cordeiro, AX Silva… - Radiation Physics and …, 2014 - Elsevier
The reference adult male voxel phantom recommended by International Commission on
Radiological Protection no. 110 was implemented in the Geant4 Monte Carlo code. Geant4 …

Dose reconstruction of a Brazilian industrial gamma radiography partial-body overexposure case

FCA Da Silva, JG Hunt, AT Ramalho… - Journal of …, 2005 - iopscience.iop.org
In May 2000, an operator of a 60 Co industrial gamma radiography apparatus, during a
routine service, was involved in a partial-body radiological accident, which caused serious …