[HTML][HTML] Alignment options for total knee arthroplasty: a systematic review

C Rivière, F Iranpour, E Auvinet, S Howell… - … & Traumatology: Surgery …, 2017 - Elsevier
In spite of improvements in implant designs and surgical precision, functional outcomes of
mechanically aligned total knee arthroplasty (MA TKA) have plateaued. This suggests …

[HTML][HTML] Kinematic alignment technique for total hip and knee arthroplasty: the personalized implant positioning surgery

C Rivière, S Lazic, L Villet, Y Wiart… - EFORT Open …, 2018 - eor.bioscientifica.com
Conventional techniques for hip and knee arthroplasty have led to good long-term clinical
outcomes, but complications remain despite better surgical precision and improvements in …

Measurement of the posterior tibial slope depends on ethnicity, sex, and lower limb alignment: a computed tomography analysis of 378 healthy participants

C Pangaud, P Laumonerie… - … journal of sports …, 2020 - journals.sagepub.com
Background: There is no general consensus on the normal and pathological values for the
posterior tibial slope (PTS). Purpose/Hypothesis: The primary aim of this study was to …

Preoperative CT-based three-dimensional templating in robot-assisted total knee arthroplasty more accurately predicts implant sizes than two-dimensional templating

JRT Pietrzak, FE Rowan, B Kayani… - The journal of knee …, 2019 - thieme-connect.com
Patient dissatisfaction after total knee arthroplasty (TKA) is a concern. Surgical error is a
common, avoidable cause of failed TKA. Correct femoral and tibial component sizing …

Sex differences in femoral deformity determined using three‐dimensional assessment for osteoarthritic knees

T Mochizuki, O Tanifuji, Y Koga, T Sato… - Knee Surgery …, 2017 - Wiley Online Library
Purpose To characterize femoral deformities and determine sex differences in varus knee
osteoarthritis (OA), femoral morphology and limb alignment were evaluated by using three …

Efficacy of the pre-operative three-dimensional (3D) CT scan templating in predicting accurate implant size and alignment in robot assisted total knee arthroplasty

SB Londhe, S Shetty, NL Vora, A Shah, R Nair… - Indian Journal of …, 2022 - Springer
Abstract Background Nearly 20% of Total knee Arthroplasty patients remain dissatisfied.
This is a major concern in twenty-first century arthroplasty practice. Accurate implant sizing is …

Relationship between coronal alignment and rotational profile of lower extremity in patients with knee osteoarthritis

MJ Chang, HJ Jeong, SB Kang, CB Chang… - The Journal of …, 2018 - Elsevier
Background We aimed at determining whether the coronal alignment of lower extremity was
related to rotational geometry of distal femur, femoral anteversion, and tibial torsion in …

Anthropometric measurements of tibial plateau and correlation with the current tibial implants

OF Erkocak, F Kucukdurmaz, S Sayar, ME Erdil… - Knee Surgery, Sports …, 2016 - Springer
Purpose The aim of the study was to make an anthropometric analysis at the resected
surfaces of the proximal tibia in the Turkish population and to compare the data with the …

[HTML][HTML] Comparison of time taken in conventional versus active robotic-assisted total knee arthroplasty

SB Londhe, S Shetty, V Shetty, C Desouza… - Clinics in Orthopedic …, 2024 - ncbi.nlm.nih.gov
Background Computer-and robotic-assisted total knee replacement procedures have been
shown to improve the accuracy of the implant size. It also allows dynamic confirmation of the …

Increased external rotation of the osteoarthritic knee joint according to the genu varum deformity

JR Yoon, JK Lee, JA Ryu, R Um, JH Yang - Knee Surgery, Sports …, 2021 - Springer
Purpose To evaluate the rotational profile of the lower extremity using computed tomography
(CT) in accordance with the degree of varus deformity in medial condyle-affected knee joint …