Review and comparison of grid-tied inverter controllers in microgrids

Q Liu, T Caldognetto, S Buso - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
Grid-tied inverters are widely used for interfacing renewable energy sources or storage
devices to low-voltage electrical power distribution systems. Lately, a number of different …

Modeling and stability analysis of $ LCL $-type grid-connected inverters: A comprehensive overview

Y Han, M Yang, H Li, P Yang, L Xu, EAA Coelho… - IEEE …, 2019 - ieeexplore.ieee.org
Due to the advantages of superior harmonics attenuation ability and reduced size, the LCL
filter has been widely adopted to interface between the inverter and the grid for improving …

Improved Design of PLL Controller for LCL-Type Grid-Connected Converter in Weak Grid

D Zhu, S Zhou, X Zou, Y Kang - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
When LCL-type converter is attached to weak grid, its current control and phase-locked loop
(PLL) will interact with each other, via the point of common coupling voltage. Unfortunately …

A Study of Virtual Resistor-Based Active Damping Alternatives for LCL Resonance in Grid-Connected Voltage Source Inverters

T Liu, J Liu, Z Liu, Z Liu - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
LCL resonance complicates the design of a current control loop and can even threaten its
stability. Extensive approaches have been proposed to deal with this resonance, among …

Comprehensive modeling, analysis, and comparison of state-space and admittance models of PLL-based grid-following inverters considering different outer control …

W Zhou, N Mohammed, B Bahrani - IEEE Access, 2022 - ieeexplore.ieee.org
The phase-locked loop (PLL)-based grid-following inverters have been widely used as the
interface between renewable energy resources (eg, wind and solar power) and the utility …

The Stability Analysis and Control Strategies of Multiparalleled SAPFs: A Comprehensive Overview

Z Wu, G Xu, W Zhu, G Sheng - IEEE Transactions on Power …, 2023 - ieeexplore.ieee.org
An active power filter (APF) is a power electrical equipment that possesses the functions of
harmonic suppression and reactive power compensation in the power grid. Its performance …

Stability analysis and auto-tuning of interlinking converters connected to weak grids

Q Liu, T Caldognetto, S Buso - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
This paper presents an adaptive multi-loop control scheme for inverters interlinking dc
voltage sources to single-phase, low-voltage ac grids. Control self-adaptation is particularly …

A passivity-based weighted proportional-derivative feedforward scheme for grid-connected inverters with enhanced harmonic rejection ability

C Wang, X Wang, Y He, X Ruan - IEEE Journal of Emerging …, 2021 - ieeexplore.ieee.org
To suppress the effect of the point of common coupling (PCC) voltage on the grid current, the
unit PCC voltage feedforward scheme is commonly applied to the grid-connected inverters …

Describing Function Method Based Power Oscillation Analysis of LCL-Filtered Single-Stage PV Generators Connected to Weak Grid

Y Xia, M Yu, X Wang, W Wei - IEEE Transactions on Power …, 2018 - ieeexplore.ieee.org
For the LCL-Filtered single-stage photovoltaic (PV) generators, the low-frequency power
oscillation (<; 50 Hz) occurs frequently when they are connected to the weak grid, whose …

Robust Control of GTIs under wide grid impedance ranges: An approach combining metaheuristics and LMIs

LC Borin, CRD Osório, GG Koch, RCLF Oliveira… - Control Engineering …, 2022 - Elsevier
This paper provides a new design procedure for robust state feedback current controllers
suitable for grid-tied inverters under wide grid impedance ranges. The proposed procedure …