Review and comparison of grid-tied inverter controllers in microgrids
Q Liu, T Caldognetto, S Buso - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
Grid-tied inverters are widely used for interfacing renewable energy sources or storage
devices to low-voltage electrical power distribution systems. Lately, a number of different …
devices to low-voltage electrical power distribution systems. Lately, a number of different …
Modeling and stability analysis of $ LCL $-type grid-connected inverters: A comprehensive overview
Due to the advantages of superior harmonics attenuation ability and reduced size, the LCL
filter has been widely adopted to interface between the inverter and the grid for improving …
filter has been widely adopted to interface between the inverter and the grid for improving …
Improved Design of PLL Controller for LCL-Type Grid-Connected Converter in Weak Grid
When LCL-type converter is attached to weak grid, its current control and phase-locked loop
(PLL) will interact with each other, via the point of common coupling voltage. Unfortunately …
(PLL) will interact with each other, via the point of common coupling voltage. Unfortunately …
A Study of Virtual Resistor-Based Active Damping Alternatives for LCL Resonance in Grid-Connected Voltage Source Inverters
LCL resonance complicates the design of a current control loop and can even threaten its
stability. Extensive approaches have been proposed to deal with this resonance, among …
stability. Extensive approaches have been proposed to deal with this resonance, among …
Comprehensive modeling, analysis, and comparison of state-space and admittance models of PLL-based grid-following inverters considering different outer control …
The phase-locked loop (PLL)-based grid-following inverters have been widely used as the
interface between renewable energy resources (eg, wind and solar power) and the utility …
interface between renewable energy resources (eg, wind and solar power) and the utility …
The Stability Analysis and Control Strategies of Multiparalleled SAPFs: A Comprehensive Overview
Z Wu, G Xu, W Zhu, G Sheng - IEEE Transactions on Power …, 2023 - ieeexplore.ieee.org
An active power filter (APF) is a power electrical equipment that possesses the functions of
harmonic suppression and reactive power compensation in the power grid. Its performance …
harmonic suppression and reactive power compensation in the power grid. Its performance …
Stability analysis and auto-tuning of interlinking converters connected to weak grids
Q Liu, T Caldognetto, S Buso - IEEE Transactions on Power …, 2019 - ieeexplore.ieee.org
This paper presents an adaptive multi-loop control scheme for inverters interlinking dc
voltage sources to single-phase, low-voltage ac grids. Control self-adaptation is particularly …
voltage sources to single-phase, low-voltage ac grids. Control self-adaptation is particularly …
A passivity-based weighted proportional-derivative feedforward scheme for grid-connected inverters with enhanced harmonic rejection ability
C Wang, X Wang, Y He, X Ruan - IEEE Journal of Emerging …, 2021 - ieeexplore.ieee.org
To suppress the effect of the point of common coupling (PCC) voltage on the grid current, the
unit PCC voltage feedforward scheme is commonly applied to the grid-connected inverters …
unit PCC voltage feedforward scheme is commonly applied to the grid-connected inverters …
Describing Function Method Based Power Oscillation Analysis of LCL-Filtered Single-Stage PV Generators Connected to Weak Grid
For the LCL-Filtered single-stage photovoltaic (PV) generators, the low-frequency power
oscillation (<; 50 Hz) occurs frequently when they are connected to the weak grid, whose …
oscillation (<; 50 Hz) occurs frequently when they are connected to the weak grid, whose …
Robust Control of GTIs under wide grid impedance ranges: An approach combining metaheuristics and LMIs
This paper provides a new design procedure for robust state feedback current controllers
suitable for grid-tied inverters under wide grid impedance ranges. The proposed procedure …
suitable for grid-tied inverters under wide grid impedance ranges. The proposed procedure …