Monte-Carlo techniques for radiotherapy applications II: equipment and source modelling, dose calculations and radiobiology
AL Fielding - Journal of Radiotherapy in Practice, 2023 - cambridge.org
Introduction: This is the second of two papers giving an overview of the use of Monte-Carlo
techniques for radiotherapy applications. Methods: The first paper gave an introduction and …
techniques for radiotherapy applications. Methods: The first paper gave an introduction and …
Coupling radiation transport and track-structure simulations: Strategy based on analytical formulas representing DNA damage yields
P Kundrát, W Friedland, A Ottolenghi, G Baiocco - Frontiers in Physics, 2021 - frontiersin.org
Existing radiation codes for biomedical applications face the challenge of dealing with
largely different spatial scales, from nanometer scales governing individual energy deposits …
largely different spatial scales, from nanometer scales governing individual energy deposits …
Collapsed cone superposition algorithm validation for chest wall tangential fields using virtual wedge filters
A Zeinali, M Molazadeh, S Ganjgahi… - Journal of Medical …, 2023 - journals.lww.com
Background: Virtual wedge (VW) is used in radiotherapy to compensate for missing tissues
and create a uniform dose distribution in tissues. According to TECDOC-1583 and technical …
and create a uniform dose distribution in tissues. According to TECDOC-1583 and technical …
[图书][B] Introduction to megavoltage x-ray dose computation algorithms
J Battista - 2019 - books.google.com
Read an exclusive interview with Dr. Jerry Battista here. A critical element of radiation
treatment planning for cancer is the accurate prediction and delivery of a tailored radiation …
treatment planning for cancer is the accurate prediction and delivery of a tailored radiation …
[HTML][HTML] Bremsstrahlung production from 10–30 MeV electrons incident on thick targets: Monte Carlo simulation with penelope
PA García-Higueras, S García-Pareja, F Salvat… - Radiation Physics and …, 2023 - Elsevier
Purpose: To study the effect of the user-defined electron/positron simulation parameters C 1
and C 2 of the Monte Carlo code penelope on the results from simulations of bremsstrahlung …
and C 2 of the Monte Carlo code penelope on the results from simulations of bremsstrahlung …
Novel Monte Carlo dose calculation algorithm for robotic radiosurgery with multi leaf collimator: Dosimetric evaluation
SC Heidorn, W Kilby, C Fürweger - Physica Medica, 2018 - Elsevier
Purpose At introduction in 2014, dose calculation for the first MLC on a robotic SRS/SBRT
platform was limited to a correction-based Finite-Size Pencil Beam (FSPB) algorithm. We …
platform was limited to a correction-based Finite-Size Pencil Beam (FSPB) algorithm. We …
Beam modeling and commissioning for Monte Carlo photon beam on an Elekta Versa HD LINAC
S Can, D Karaçetin, N Meriç - Applied Radiation and Isotopes, 2022 - Elsevier
Purpose This study aims at analyzing beam data commissioning along with verifying Monte
Carlo-based treatment planning system on the basis of the manufacturer guidelines for …
Carlo-based treatment planning system on the basis of the manufacturer guidelines for …
Linac photon beam fine-tuning in PRIMO using the gamma-index analysis toolkit
AM Bacala - Radiation Oncology, 2020 - Springer
Abstract Background In Monte Carlo simulations, the fine-tuning of linac beam parameters to
produce a good match between simulated and measured dose profiles is a lengthy, time …
produce a good match between simulated and measured dose profiles is a lengthy, time …
[HTML][HTML] Extending in aqua portal dosimetry with dose inhomogeneity conversion maps for accurate patient dose reconstruction in external beam radiotherapy
I Olaciregui-Ruiz, JM Osinga-Blaettermann… - Physics and Imaging in …, 2022 - Elsevier
Background and purpose In aqua dosimetry with electronic portal imaging devices (EPIDs)
allows for dosimetric treatment verification in external beam radiotherapy by comparing …
allows for dosimetric treatment verification in external beam radiotherapy by comparing …
Quantitative comparison of different dosimetry methods in orthovoltage X-ray therapy
A Sevcik, J Laurikaitiene, D Adliene - Radiation Physics and Chemistry, 2022 - Elsevier
Gamma index metric is frequently used for dose verification in quality control (QC)
procedures for clinical radiation therapy. Monte Carlo (MC) simulations and radiochromic …
procedures for clinical radiation therapy. Monte Carlo (MC) simulations and radiochromic …