BeOSL dosemeters and new ICRU operational quantities: Response of existing dosemeters and modification options
H Hoedlmoser, V Bandalo, M Figel - Radiation Measurements, 2020 - Elsevier
The energy response for angles of incidence of 0° and 60° of current BeOSL H p (10)-, H p
(3)-, H p (0, 07)-and H*(10) dosemeters for photon radiation has been expressed in terms of …
(3)-, H p (0, 07)-and H*(10) dosemeters for photon radiation has been expressed in terms of …
[HTML][HTML] Performance of radiophotoluminescence personal dosimeters in terms of the ICRU Report 95's operational quantities
The objective of this work is to assess the photon energy and angle response of the
radiophotoluminescence (RPL) personal dosimetry system used at the Paul Scherrer …
radiophotoluminescence (RPL) personal dosimetry system used at the Paul Scherrer …
[HTML][HTML] Implications of the ICRU 95 quantities for various personal dosimetry techniques
L Bossin, P Carbonez, JB Christensen, M Furlan… - Radiation …, 2024 - Elsevier
The objective of this work is to assess the photon energy and angular response of various
dosimetry systems in terms of the operational quantities for external radiation exposure …
dosimetry systems in terms of the operational quantities for external radiation exposure …
Present and New Operational Quantities Evaluated from Photon Spectrum Measurements at workplaces in the Research Reactor and Accelerator Facility at the JAEA
Y Tanimura, H Yoshitomi, S Nishino, T Tsuji… - Radiation …, 2024 - Elsevier
ABSTRACT The International Commission on Radiation Units and Measurements (ICRU)
has proposed to change the definitions of the operational quantities used for the area and …
has proposed to change the definitions of the operational quantities used for the area and …
Response of current dosemeters to new operational quantities in rotational geometry
Z Čemusová, D Ekendahl, D Kurková… - Radiation Protection …, 2023 - academic.oup.com
Recently, the ICRU released Report 95, where new operational quantities for external
radiation exposure are defined. The new quantities are defined in close relation to the …
radiation exposure are defined. The new quantities are defined in close relation to the …
[HTML][HTML] 实用量的最新进展及其影响
刘澜涛, 尉可道 - 中国辐射卫生, 2023 - html.rhhz.net
随着更多类型, 更宽能量范围辐射的应用, 现行实用量由于存在一些概念缺陷,
其适用范围严重受限, 为此国际辐射单位和测量委员会(ICRU) 提出了新的实用量 …
其适用范围严重受限, 为此国际辐射单位和测量委员会(ICRU) 提出了新的实用量 …
ICRU 95 号报告: 外照射实用量及其对剂量学的影响
H Menzel, T Otto - 辐射防护, 2023 - journal01.magtech.org.cn
国际放射防护委员会(ICRP) 提出了“防护量” 这一概念. 最常用的防护量, 即有效剂量E,
用于设定照射限值, 并在实用辐射防护中使用, 以实现最优化原则. 然而, 有效剂量不是一个可 …
用于设定照射限值, 并在实用辐射防护中使用, 以实现最优化原则. 然而, 有效剂量不是一个可 …
Response of a TLD badge to the new operational quantity Hp (θ): Monte Carlo approach
IO Polo, WS Santos, CV de Moraes… - Radiation Physics and …, 2022 - Elsevier
Abstract In 2020, the International Commission on Radiation Units and Measurements'
Report Committee 26 (RC 26) proposed new operational quantities to be used in personal …
Report Committee 26 (RC 26) proposed new operational quantities to be used in personal …
Impact of new ICRU dose quantities on rem-meters and on the operational radiation protection in compact proton therapy centers (CPTC)
Area monitoring in proton therapy centers is carried out using neutron detectors placed at
critical locations of the facility. Currently, neutron survey devices, known as REM-meters, are …
critical locations of the facility. Currently, neutron survey devices, known as REM-meters, are …
Response of Current Area Dosemeters to New Operational Quantities
Z Čemusová, D Ekendahl, L Judas… - Radiation Protection …, 2022 - academic.oup.com
New operational quantities for external radiation exposure presented by the ICRU brought
changes, which can affect the use of current dosemeters. Dosemeters calibrated in the old …
changes, which can affect the use of current dosemeters. Dosemeters calibrated in the old …