Nonlinear finite-element analysis for predicting the behavior of concrete squat walls reinforced with GFRP bars

A Arafa, AS Farghaly, B Benmokrane - Journal of Structural …, 2019 - ascelibrary.org
The recent experimental results for squat walls reinforced entirely with glass-fiber-reinforced-
polymer (GFRP) bars have demonstrated their feasibility in resisting lateral loads and …

Evaluation of the seismic performance of novel bundled connections precast shear walls under cyclic loading

J Feng, Z Yu, G Liu, X Fan, Q Zhang… - Structural Concrete, 2024 - Wiley Online Library
This study proposes a novel precast shear wall connection method for connecting upper and
lower wall panels. The vertical steel bars within the lower prefabricated wall panels are …

Experimental Study on Seismic Performance of Partially Corroded Squat RC Shear Walls in Coastal Environment

Y Song, J Wang, J Du - Buildings, 2024 - mdpi.com
In coastal environments, squat reinforced concrete (RC) shear walls are susceptible to local
accumulation of moisture and chloride salts, causing local corrosion in the shear walls …

[HTML][HTML] Effects of Openings and Axial Load Ratio on the Lateral Capacity of Steel-Fiber-Reinforced Concrete Shear Walls

Z Lin, H Zhang, G Monti, C Castoro - Buildings, 2022 - mdpi.com
Shear walls are commonly adopted as main structural members to resist vertical and lateral
forces, thanks to their high load capacity and high lateral stiffness. However, their lateral …

Deformation capacity limits for reinforced concrete walls

AV Shegay, CJ Motter, KJ Elwood… - Earthquake …, 2019 - journals.sagepub.com
The use of deformation capacity limits is becoming increasingly common in seismic design
and assessment of reinforced concrete (RC) walls. Deformation capacity limits for RC walls …

钢筋混凝土剪力墙塑性铰长度计算模型研究

王义俊, 汪梦甫 - 工业建筑, 2016 - cqvip.com
钢筋混凝土剪力墙塑性铰长度对剪力墙延性和耗能能力有重要影响, 而已有的剪力墙塑性铰长度
计算模型给出的主要影响因素各有不同. 为了准确确定剪力墙塑性铰长度的主要影响因素 …

Understanding the behavior of the Thin Lightly-Reinforced Concrete Wall (TLRCW) building system

R Bonett, J Carrillo, C Blandón… - Journal of Structural …, 2024 - Taylor & Francis
Thin lightly reinforced concrete wall (TLRCW) buildings are commonly used to mitigate the
housing deficit in developing countries. The TLRCW system comprises slender walls with a …

Exploratory study on incorporating glass FRP reinforcement to control damage in steel-reinforced concrete bridge pier walls

A Arafa, N Ahmed, AS Farghaly, O Chaallal… - Journal of Bridge …, 2021 - ascelibrary.org
The need to demonstrate that a steel-reinforced concrete bridge pier wall resilient to strong
earthquakes could be attained by the incorporation of glass fiber–reinforced polymer …

[HTML][HTML] 核电工程双钢板混凝土剪力墙面外受弯性能

李小军, 李晓虎 - 哈尔滨工程大学学报, 2017 - html.rhhz.net
为了研究核电工程双钢板混凝土组合剪力墙在面外荷载作用下的抗震性能, 本文对6
个剪力墙试件进行了低周往复荷载试验. 制作的试件包括5 个双钢板混凝土组合剪力墙试件和1 …

Impact of CFRP partial bonding on the behaviour of short reinforced concrete wall under monotonic lateral loading

S Qazi, L Michel, E Ferrier - Composite Structures, 2015 - Elsevier
The present research work highlights the significance of partially bonding Carbon Fiber
Reinforced Polymer to RC walls to attain reasonable strength and drift without deteriorating …