A robust fractional-order control scheme for PV-penetrated grid-connected microgrid
This article presents a new cascaded control strategy to control the power flow in a
renewable-energy-based microgrid operating in grid-connected mode. The microgrid model …
renewable-energy-based microgrid operating in grid-connected mode. The microgrid model …
Internal model based smooth transition of a three-phase inverter between islanded and grid-connected modes
S Yazdani, M Ferdowsi… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
Recent technical advances in control, protection and interconnection of distributed power
generation units imply that it is practically viable and economically profitable to keep them as …
generation units imply that it is practically viable and economically profitable to keep them as …
Model predictive control of a three-phase two-level four-leg grid-connected converter based on sphere decoding method
B Long, T Cao, W Fang, KT Chong… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
To achieve optimal control of four-leg grid-connected converters in terms of switching
frequency and current tracking, the finite-control-set model-predictive-control method (FCS …
frequency and current tracking, the finite-control-set model-predictive-control method (FCS …
Internal Model Based Grid Voltage Estimation and Control of a Three-Phase Grid Connected Inverter for Application
VR Chowdhury - IEEE Transactions on Energy Conversion, 2021 - ieeexplore.ieee.org
Grid connected inverter controllers require the magnitude and phase of the point of common
coupling voltage for the generation of unit vectors from a phase locked loop. However, weak …
coupling voltage for the generation of unit vectors from a phase locked loop. However, weak …
Disturbance Observer-Based Control for Three-Phase Grid-Tied Inverter With LCL Filter
This article presents the design and performance evaluation of disturbance observer-based
control for grid-tied inverter with LCL filter. The proposed controller consists of a combination …
control for grid-tied inverter with LCL filter. The proposed controller consists of a combination …
Improvement of Transient Performance in Microgrids: Comprehensive Review on Approaches and Methods for Converter Control and Route of Grid Stability
In conventional power systems, stability is ensured successfully because of large
synchronous generators, where, during transient conditions, the inertia and dynamics of the …
synchronous generators, where, during transient conditions, the inertia and dynamics of the …
[HTML][HTML] 2DOF-based current controller for single-phase grid-connected voltage source inverter applications
FJ López-Alcolea, EJ Molina-Martínez, AP Torres… - Applied Energy, 2023 - Elsevier
This paper presents the design of a discrete-time control scheme for the current injected into
the grid by a single-phase voltage source inverter (VSI). The VSI is connected to the grid by …
the grid by a single-phase voltage source inverter (VSI). The VSI is connected to the grid by …
Continuous control set model predictive current control of a microgrid-connected pwm inverter
This paper deals with a novel control architecture for pulse width modulation inverters
connected to the grid through resonant LCL filters. A continuous-control-set model predictive …
connected to the grid through resonant LCL filters. A continuous-control-set model predictive …
Comparison of current control strategies based on FCS-MPC and D-PI-PWM control for actively damped VSCs with LCL-filters
This paper presents a comparative study of the proportional-integral-based (PI-based)
synchronous current control strategy with derivative-feedback-based active damping and the …
synchronous current control strategy with derivative-feedback-based active damping and the …
Stability enhancement of LCL-type grid-following inverters using capacitor voltage active damping
An LCL filter offers superior attenuation for high-frequency harmonics for three-phase grid-
following inverters compared to LC and L filters. However, it also introduces an inherent …
following inverters compared to LC and L filters. However, it also introduces an inherent …