A novel approach to EPID-based 3D volumetric dosimetry for IMRT and VMAT QA
Intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT)
are relatively complex treatment delivery techniques and require quality assurance (QA) …
are relatively complex treatment delivery techniques and require quality assurance (QA) …
A regression‐based approach to compute the pixels sensitivity map of linear accelerator portal imaging devices
M Ahmad, H Nourzadeh, J Siebers - Medical Physics, 2021 - Wiley Online Library
Purpose To determine the pixel sensitivity map (PSM) for amorphous silicon electronic portal
imaging devices (EPIDs) using a single flood field signal. Method and materials A raw EPID …
imaging devices (EPIDs) using a single flood field signal. Method and materials A raw EPID …
A simple algorithm to convert EPID gray values into absorbed dose to water without prior knowledge
C Boutry, A Sors, J Fontaine, N Delaby… - Medical …, 2017 - Wiley Online Library
Purpose Full integration of EPID‐based dosimetry in a global quality control workflow is still
complicated. All the actual solutions are based on a relation between image gray‐level …
complicated. All the actual solutions are based on a relation between image gray‐level …
[PDF][PDF] EPID-based 3D dosimetry for pre-treatment IMRT/VMAT quality assurance
A Alhazmi - 2018 - edoc.ub.uni-muenchen.de
Abstract Treatment of cancer using photon radiation has rapidly developed in the last few
decades. The development has aimed at improving the therapeutic ratio by delivering a …
decades. The development has aimed at improving the therapeutic ratio by delivering a …
Análisis del control de calidad dosimétrico para tratamiento de arcoterapia volumétrica de intensidad modulada comparando un arreglo cilíndrico de diodos y …
JM Moscoso Carrasco - 2022 - 190.12.84.13
La Arcoterapia Volumétrica Modulada (Volumetric Modulated Arc Therapy, VMAT) es una
de las técnicas modernas más usadas para brindar tratamiento oncológico dentro del área …
de las técnicas modernas más usadas para brindar tratamiento oncológico dentro del área …
System and method to compute a pixel sensitivity map of an imaging device
JV Siebers, M Ahmed - US Patent 11,850,448, 2023 - Google Patents
An image calibration method includes capturing and correcting a flood field image for
background signal and effects of known image-panel features (dead/bad pixels). The …
background signal and effects of known image-panel features (dead/bad pixels). The …
System and method to compute a pixel sensitivity map of an imaging device
JV Siebers, M Ahmed - US Patent 11,565,133, 2023 - Google Patents
An image calibration method includes capturing and correcting a flood field image for
background signal and effects of known image-panel features (dead/bad pixels). The …
background signal and effects of known image-panel features (dead/bad pixels). The …
Development of a Fluence Generating Programme for Patient-Specific Quality Assurance and Calibration of an Amorphous Silicon EPID
Patient-specific quality assurance (QA) is an essential part of intensity-modulated
radiotherapy (IMRT) and volumetric arc therapy (VMAT) treatments. This study aims to …
radiotherapy (IMRT) and volumetric arc therapy (VMAT) treatments. This study aims to …