Smart materials in cardiovascular implants: Shape memory alloys and shape memory polymers

H Holman, MN Kavarana, TK Rajab - Artificial organs, 2021 - Wiley Online Library
Smart materials have intrinsic properties that change in a controlled fashion in response to
external stimuli. Currently, the only smart materials with a significant clinical impact in …

[HTML][HTML] The technological basis of a balloon-expandable TAVR system: non-occlusive deployment, anchorage in the absence of calcification and polymer leaflets

H Appa, K Park, D Bezuidenhout… - Frontiers in …, 2022 - frontiersin.org
Leaflet durability and costs restrict contemporary trans-catheter aortic valve replacement
(TAVR) largely to elderly patients in affluent countries. TAVR that are easily deployable …

Transcatheter Aortic Valve Implantation With and Without Resheathing and Repositioning: A Systematic Review and Meta‐analysis

F Moroni, L Azzalini, L Sondergaard… - Journal of the …, 2022 - Am Heart Assoc
Background There is a concern that resheathing/repositioning of transcatheter heart valves
during transcatheter aortic valve implantation (TAVI) may lead to an increased risk of …

Incidence, predictor, and clinical outcomes of multiple resheathing with self‐expanding valves during transcatheter aortic valve replacement

FLM Bernardi, J Rodés‐Cabau… - Journal of the …, 2021 - Am Heart Assoc
Background No study has evaluated the impact of the additional manipulation demanded by
multiple resheathing (MR) in patients undergoing transcatheter aortic valve replacement …

[HTML][HTML] Clinical impact of multiple resheathing during transcatheter aortic valve implantation with Evolut self-expanding valves

C Aurigemma, M Busco, F Bianchini, E Bianchini… - International Journal of …, 2024 - Elsevier
Background The possibility to resheath some transcatheter heart valves (THV) facilitates the
optimization of self-expandable devices implantation. However, resheating manoeuvres …

Resheathing and repositioning during transcatheter aortic valve implantation

R Bagur - Journal of the American Heart Association, 2021 - Am Heart Assoc
The Evolut platform (Medtronic, Minneapolis, MN) and the Portico (Abbott, Abbott Park, IL)
are selfexpanding transcatheter heart valves (THVs) designed with recapturable and …

Incidence and predictors of structural valve deterioration after transcatheter aortic valve replacement: a systematic review and meta‐analysis

YX Long, ZZ Liu - Journal of Interventional Cardiology, 2020 - Wiley Online Library
Background. Transcatheter aortic valve replacement (TAVR), widely used as an alternative
therapy in patients with severe aortic stenosis, is expected to be offered to low‐risk patents …

[HTML][HTML] Impact of Nodular Calcifications in the Aortic Annulus and Left Ventricular Outflow Tract on TAVI Outcome with New-Generation Devices

R Gorla, OA Oliva, E Poletti, A Finotello… - Reviews in …, 2022 - imrpress.com
Background: The impact of nodular calcifications in left ventricular outlow tract (LVOT) and
aortic annulus on the procedural outcome of transcatheter aortic valve implantation (TAVI) …

[HTML][HTML] How to use the aortic valve calcium score to improve the results of transcatheter aortic valve implantation with a self-expanding prosthesis

G Clerfond, N Combaret, JP Salazard, A Innorta… - Archives of …, 2022 - Elsevier
Background In recent years, transcatheter aortic valve implantation (TAVI) without
predilation (direct TAVI) has become the preferred method for implanting TAVI prostheses …

The Technological Basis of a Balloon-Expandable TAVR System: Non-occlusive Deployment, Anchorage in the Absence of Calcification and Polymer Leaflets

M Nunes, A Iadanza, DC Reineke, P Zilla… - Global Frontiers in …, 2022 - books.google.com
Appa et al. A Universal Balloon-Expandable TAVR System pressure gradients and
regurgitation volumes. Post-deployment fatigue resistance surpassed ISO requirements. The …