Dosimetry of ionising radiation in modern radiation oncology

T Kron, J Lehmann, PB Greer - Physics in Medicine & Biology, 2016 - iopscience.iop.org
Dosimetry of ionising radiation is a well-established and mature branch of physical sciences
with many applications in medicine and biology. In particular radiotherapy relies on …

Report of the Task Group 186 on model‐based dose calculation methods in brachytherapy beyond the TG‐43 formalism: current status and recommendations for …

L Beaulieu, Å Carlsson Tedgren, JF Carrier… - Medical …, 2012 - Wiley Online Library
The charge of Task Group 186 (TG‐186) is to provide guidance for early adopters of model‐
based dose calculation algorithms (MBDCAs) for brachytherapy (BT) dose calculations to …

Dose calculation algorithm accuracy for small fields in non-homogeneous media: The lung SBRT case

A Fogliata, L Cozzi - Physica Medica, 2017 - Elsevier
This review addresses the theme of dose calculation accuracy in the case of the stereotactic
treatment of lung lesions. Based on the classical categories of type “a”,“b” and “c” algorithms …

Dose calculation for photon‐emitting brachytherapy sources with average energy higher than 50 keV: report of the AAPM and ESTRO

J Perez‐Calatayud, F Ballester, RK Das… - Medical …, 2012 - Wiley Online Library
Purpose: Recommendations of the American Association of Physicists in Medicine (AAPM)
and the European Society for Radiotherapy and Oncology (ESTRO) on dose calculations for …

Dosimetric validation of Acuros® XB with Monte Carlo methods for photon dose calculations

K Bush, IM Gagne, S Zavgorodni, W Ansbacher… - Medical …, 2011 - Wiley Online Library
Purpose: The dosimetric accuracy of the recently released Acuros® XB advanced dose
calculation algorithm (Varian Medical Systems, Palo Alto, CA) is investigated for single …

Dosimetric comparison of Acuros XB deterministic radiation transport method with Monte Carlo and model‐based convolution methods in heterogeneous media

T Han, JK Mikell, M Salehpour, F Mourtada - Medical Physics, 2011 - Wiley Online Library
Purpose: The deterministic Acuros XB (AXB) algorithm was recently implemented in the
Eclipse treatment planning system. The goal of this study was to compare AXB performance …

Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media

A Fogliata, G Nicolini, A Clivio, E Vanetti, L Cozzi - Radiation oncology, 2011 - Springer
Background A study was realised to evaluate and determine relative figures of merit of a
new algorithm for photon dose calculation when applied to inhomogeneous media. Methods …

Performance of dose calculation algorithms from three generations in lung SBRT: comparison with full Monte Carlo‐based dose distributions

JJ Ojala, MK Kapanen, SJ Hyödynmaa… - Journal of applied …, 2014 - Wiley Online Library
The accuracy of dose calculation is a key challenge in stereotactic body radiotherapy
(SBRT) of the lung. We have benchmarked three photon beam dose calculation algorithms …

AAPM Task Group 329: reference dose specification for dose calculations: dose‐to‐water or dose‐to‐muscle?

SF Kry, V Feygelman, P Balter, T Knöös… - Medical …, 2020 - Wiley Online Library
Linac calibration is done in water, but patients are comprised primarily of soft tissue.
Conceptually, and specified in NRG/RTOG trials, dose should be reported as dose‐to …

Dosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated arc therapy …

PS Kroon, S Hol, M Essers - Radiation oncology, 2013 - Springer
Introduction The main aim of the current study was to assess the dosimetric accuracy and
clinical quality of volumetric modulated arc therapy (VMAT) plans for stereotactic (stage I) …