Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to …

T Nagaoka, S Watanabe, K Sakurai… - Physics in Medicine …, 2003 - iopscience.iop.org
With advances in computer performance, the use of high-resolution voxel models of the
entire human body has become more frequent in numerical dosimetries of electromagnetic …

[图书][B] The phantoms of medical and health physics

LA DeWerd, M Kissick - 2014 - Springer
Phantoms, devices that represent the human body, have been used in medical physics and
health physics since the beginning. Soon after the discovery of X-rays, news of the medical …

Construction of a computed tomographic phantom for a Japanese male adult and dose calculation system

K Saito, A Wittmann, S Koga, Y Ida, T Kamei… - Radiation and …, 2001 - Springer
Computational human phantoms have been widely used to estimate organ doses and other
dosimetric quantities related to the human body where direct measurements are difficult to …

Fluence-to-dose conversion coefficients from monoenergetic neutrons below 20 MeV based on the VIP-man anatomical model

A Bozkurt, TC Chao, XG Xu - Physics in Medicine & Biology, 2000 - iopscience.iop.org
A new set of fluence-to-absorbed dose and fluence-to-effective dose conversion coefficients
have been calculated for neutrons below 20 MeV using a whole-body anatomical model …

Fluence-to-dose conversion coefficients based on the VIP-Man anatomical model and MCNPX code for monoenergetic neutrons above 20 MeV

A Bozkurt, TC Chao, XG Xu - Health Physics, 2001 - journals.lww.com
A new set of fluence-to-absorbed dose and fluence-to-effective dose conversion coefficients
has been calculated for high-energy neutrons using a whole-body anatomical model, VIP …

Neutron-fluence-to-dose conversion coefficients in an anthropomorphic phantom

AA Alghamdi, A Ma, M Tzortzis… - Radiation protection …, 2005 - academic.oup.com
A set of fluence-to-effective-dose conversion coefficients has been calculated for neutrons
with energies< 20 MeV using a high-resolution anthropomorphic phantom (Zubal model) …

Effective doses and organ doses per unit fluence calculated for monoenergetic 0.1 MeV to 100 MeV electrons by the MIRD-5 phantom

M Katagiri, M Hikoji, M Kitaichi… - Radiation protection …, 2000 - academic.oup.com
To determine quantities for radiation protection against high energy electrons, such as those
from LINAC, the organ doses and effective doses were calculated using EGS-4 Monte Carlo …

Sex-specific tissue weighting factors for effective dose equivalent calculations

XG Xu, WD Reece - Health physics, 1996 - journals.lww.com
The effective dose equivalent was defined in the International Commission on Radiological
Protection Publication 26 in 1977 and later adopted by the US Nuclear Regulatory …

Neutron dose equivalent rates calculated from measured neutron angular and energy distributions in working environments

P Drake, DT Bartlett - Radiation protection dosimetry, 1997 - academic.oup.com
The estimation of non-isotropic neutron dose equivalent quantities in multidirectional fields
is complicated. The estimation must be based on the neutron fluence rate as a function of …

[PDF][PDF] Overview of Fluence to Dose Equivalent Conversion Coefficients for High-energy Radiations: Calculational Methods and Results of Two Kinds of Effective …

S Iwai, T Uehara, O Sato, N Yoshizawa… - Shielding Aspects of …, 1999 - oecd-nea.org
In and around high-energy accelerator facilities, high-energy radiation dose estimation is
important for the radiological protection of workers. The contribution of high-energy protons …