Percutaneous interventions for left atrial appendage exclusion: options, assessment, and imaging using 2D and 3D echocardiography

NC Wunderlich, R Beigel, MJ Swaans, SY Ho… - JACC: Cardiovascular …, 2015 - jacc.org
Percutaneous left atrial appendage (LAA) exclusion is an evolving treatment to prevent
embolic events in patients with nonvalvular atrial fibrillation. In the past few years multiple …

Three-dimensional transesophageal echocardiography is a major advance for intraoperative clinical management of patients undergoing cardiac surgery: a core …

A Vegas, M Meineri - Anesthesia & Analgesia, 2010 - journals.lww.com
Echocardiography is a key assessment tool for the evaluation of cardiac structure and
function. The ability to image cardiac structures using 3-dimensional (3D) echocardiography …

Complications associated with transesophageal echocardiography in transcatheter structural cardiac interventions

AA Hasnie, V Parcha, R Hawi, M Trump… - Journal of the American …, 2023 - Elsevier
Background Transesophageal echocardiograms (TEEs) performed during transcatheter
structural cardiac interventions may result in greater complications than those performed in …

4-D ICE: A 2-D array transducer with integrated ASIC in a 10-Fr catheter for real-time 3-D intracardiac echocardiography

D Wildes, W Lee, B Haider, S Cogan… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
We developed a 2.5× 6.6 mm 2 2-D array transducer with integrated transmit/receive
application-specific integrated circuit (ASIC) for real-time 3-D intracardiac echocardiography …

Methods and devices for treating atrial fibrillation

GW Fung, RA Seiber, R Strasser, AM Escano… - US Patent …, 2019 - Google Patents
Described here are systems and methods for affecting tissue within a body to form a lesion.
Some systems comprise tissue-affecting devices, devices that guide the advancement of the …

Methods and devices for accessing and delivering devices to a heart

GW Fung, RA Seiber, R Strasser… - US Patent 9,486,281, 2016 - Google Patents
A61B 18/00(2006.01) 5,683,364 A 11/1997 Zadini et al. A61N 7/OO 2006. O1 5,683.445 A 1
1/1997 Swoyer (2006.01) 5,693,059 A 12/1997 Yoon (52) US Cl. 5,693,091 A 12/1997 …

Transcatheter closure of paravalvular defects using a purpose-specific occluder

F Nietlispach, M Johnson, RR Moss… - JACC: Cardiovascular …, 2010 - jacc.org
Objectives: This study sought to describe a method of paravalvular leak closure using a
purpose-specific occlusion device. Background: Transcatheter closure of paravalvular leaks …

3D TEE during catheter-based interventions

FF Faletra, G Pedrazzini, E Pasotti, S Muzzarelli… - JACC: Cardiovascular …, 2014 - jacc.org
Guidance of catheter-based procedures is performed using fluoroscopy and 2-dimensional
transesophageal echocardiography (TEE). Both of these imaging modalities have significant …

A pitch-matched transceiver ASIC with shared hybrid beamforming ADC for high-frame-rate 3-D intracardiac echocardiography

YM Hopf, BW Ossenkoppele… - IEEE Journal of Solid …, 2022 - ieeexplore.ieee.org
In this article, an application-specific integrated circuit (ASIC) for 3-D, high-frame-rate
ultrasound imaging probes is presented. The design is the first to combine element-level …

Real-time 3D transesophageal echocardiography for the evaluation of rheumatic mitral stenosis

D Schlosshan, G Aggarwal, G Mathur, R Allan… - JACC: Cardiovascular …, 2011 - jacc.org
Objectives: The aims of this study were: 1) to assess the feasibility and reliability of
performing mitral valve area (MVA) measurements in patients with rheumatic mitral valve …