TLD calibration and absorbed dose measurement in a radiation-induced liver injury model under a linear accelerator
HH Xiao, LL Liu, WY Li, BB Li, XL Cui, J Li, TS Li… - Nuclear Science and …, 2023 - Springer
The application of a thermoluminescent detector (TLD) for dose detection at the liver
irradiation site in mice under linear accelerator precision radiotherapy and the use of a …
irradiation site in mice under linear accelerator precision radiotherapy and the use of a …
A structure-based gamma evaluation method for identifying clinically relevant dose differences in organs at risk
Gamma evaluation is currently the most widely used dose comparison method for patient
specific quality assurance (PSQA). However, existing methods for normalising the dose …
specific quality assurance (PSQA). However, existing methods for normalising the dose …
Sensitivity and specificity of secondary dose calculation for head and neck treatment plans
Purpose Secondary dose calculation (SDC) with an independent algorithm is one option to
perform plan‐specific quality assurance (QA). While measurement‐based QA can potentially …
perform plan‐specific quality assurance (QA). While measurement‐based QA can potentially …
Beam modeling and commissioning for Monte Carlo photon beam on an Elekta Versa HD LINAC
S Can, D Karaçetin, N Meriç - Applied Radiation and Isotopes, 2022 - Elsevier
Purpose This study aims at analyzing beam data commissioning along with verifying Monte
Carlo-based treatment planning system on the basis of the manufacturer guidelines for …
Carlo-based treatment planning system on the basis of the manufacturer guidelines for …
Development of a new MC Fast Dose Engine for small compact radiation fields generated by the CyberKnifeⓇ Iris medical linac
D Krim, A El Outmani, FZ El Hadri, M Zerfaoui… - Radiation Physics and …, 2023 - Elsevier
MC-based computerized TPS is an essential tool for improving treatment quality in external
radiation therapy chains. However, incorporating these systems into clinical TPS is …
radiation therapy chains. However, incorporating these systems into clinical TPS is …
Recommendations for simulating and measuring with biofabricated lung equivalent materials based on atomic composition analysis
Monte Carlo simulations of lung equivalent materials often involve the density being
artificially lowered rather than a true lung tissue (or equivalent plastic) and air composition …
artificially lowered rather than a true lung tissue (or equivalent plastic) and air composition …
Exploring the gamma surface: a new method for visualising modulated radiotherapy quality assurance results
Purpose This work presents a novel method of visualising the results of patient-specific
quality assurance (QA) for modulated radiotherapy treatment plans, using a three …
quality assurance (QA) for modulated radiotherapy treatment plans, using a three …
Monte Carlo calculations of radiotherapy dose in “homogeneous” anatomy
Given the substantial literature on the use of Monte Carlo (MC) simulations to verify
treatment planning system (TPS) calculations of radiotherapy dose in heterogeneous …
treatment planning system (TPS) calculations of radiotherapy dose in heterogeneous …
蒙特卡罗治疗计划系统MMCTP 的临床评估.
孟慧鹏, 孙小喆, 付娟, 段敬豪… - Chinese Medical …, 2022 - search.ebscohost.com
目的院研究McGill 大学开发的蒙特卡罗治疗计划系统MMCTP (McGill Monte Carlo treatment
planning system) 用于临床剂量学研究的可行性. 方法院选取某院2012 年6 月至2016 年12 …
planning system) 用于临床剂量学研究的可行性. 方法院选取某院2012 年6 月至2016 年12 …
Implementace softwaru pro automatizovanou kontrolu RT plánu a jeho doručení v klinické praxi
C Magdaléna - 2023 - dspace.cvut.cz
Cílem diplomové práce bylo nastavit akční a toleranční limity pro kvalitu radioterapeutického
plánu, nezávislý výpočet dávky a pro rekonstrukci doručené dávky v softwarech Mobius3D a …
plánu, nezávislý výpočet dávky a pro rekonstrukci doručené dávky v softwarech Mobius3D a …