Scalar localization by cone-beam computed tomography of cochlear implant carriers: a comparative study between straight and periomodiolar precurved electrode …

E Boyer, A Karkas, A Attye, V Lefournier… - Otology & …, 2015 - journals.lww.com
Scalar Localization by Cone-Beam Computed Tomography of Coch... : Otology &
Neurotology Scalar Localization by Cone-Beam Computed Tomography of Cochlear …

Evaluation of cochlear duct length computations using synchrotron radiation phase-contrast imaging

RW Koch, M Elfarnawany, N Zhu, HM Ladak… - Otology & …, 2017 - journals.lww.com
Background: Various relationships relating A value measured from a patient's computed
tomography scan and CDL have been proposed to aid in preoperative electrode selection …

Reliability of cone beam computed tomography in scalar localization of the electrode array: a radio histological study

M Marx, F Risi, B Escudé, I Durmo, C James… - European Archives of …, 2014 - Springer
Postoperative imaging plays a growing role in clinical studies concerning prognostic factors
in cochlear implantation. Indeed, intracochlear position of the cochlear implant has recently …

Assessment of cochlear trauma during cochlear implantation using electrocochleography and cone beam computed tomography

A Dalbert, A Huber, D Veraguth, C Roosli… - Otology & …, 2016 - journals.lww.com
Objective: To assess cochlear trauma during cochlear implantation by electrocochleography
(ECoG) and cone beam computed tomography (CBCT) and to correlate intraoperative …

Electrode translocations in perimodiolar cochlear implant electrodes: audiological and electrophysiological outcome

T Liebscher, A Mewes, U Hoppe, J Hornung… - … für Medizinische Physik, 2021 - Elsevier
Introduction Despite using the soft-surgery technique, cochlear implantation may increase
the damage of the intracochlear structures due to a scalar translocation of the electrode. The …

Visualization, measurement and modelling of the cochlea using rotating midmodiolar slice planes

GJ Lexow, D Schurzig, NC Gellrich, T Lenarz… - International journal of …, 2016 - Springer
Purpose Cross-sectional visualization of anatomical structures in DICOM viewers is usually
presented in parallel slices. For visualizing the inner ear, this concept is unfavourable due to …

Cone-beam CT versus multi-slice CT systems for postoperative imaging of cochlear implantation—a phantom study on image quality and radiation exposure using …

HJ Theunisse, RMS Joemai, TJJ Maal… - Otology & …, 2015 - journals.lww.com
Background CBCT has been described as a low-dose alternative with superior image
quality to MSCT for postoperative cochlear implant (CI) imaging, but to our knowledge, no …

[HTML][HTML] 3D curved multiplanar cone beam CT reconstruction for intracochlear position assessment of straight electrodes array. A temporal bone and clinical study

D De Seta, P Mancini, FY Russo, R Torres… - Acta …, 2016 - ncbi.nlm.nih.gov
SUMMARY A retrospective review of post-op cone beam CT (CBCT) of 8 adult patients and
14 fresh temporal bones that underwent cochlear implantation with straight flexible …

On the accuracy of cochlear duct length measurement in computed tomographic images

GJ Lexow, M Kluge, NC Gellrich, T Lenarz… - European Archives of …, 2018 - Springer
Purpose Patient specific selection of cochlear implants would benefit from pre-operative
knowledge of cochlear length. Several methods for its measurement or estimation have …

Effects of electrode array length on frequency-place mismatch and speech perception with cochlear implants

F Venail, C Mathiolon… - Audiology and …, 2015 - karger.com
Frequency-place mismatch often occurs after cochlear implantation, yet its effect on speech
perception outcome remains unclear. In this article, we propose a method, based on cochlea …