Comparison of BNCT dosimetry calculations using different GEANT4 physics lists
Z Chen, P Yang, Q Lei, Y Wen, D He… - Radiation protection …, 2019 - academic.oup.com
A comparison of Geant4 physics lists is conducted in the calculation of the total absorbed
dose, boron dose, and non-boron dose in phantom, and the total depth-dose, boron depth …
dose, boron dose, and non-boron dose in phantom, and the total depth-dose, boron depth …
Design of a protective shield for a radiological emergency intervention using Monte Carlo simulation and an anthropomorphic phantom
Due to the increasing use of radioactive sources, new challenges appear for the protection
of humans and the environment against ionizing radiation. Thus, organizations handling …
of humans and the environment against ionizing radiation. Thus, organizations handling …
A Monte Carlo study of SPECT in boron neutron capture therapy for a heterogeneous human phantom
Boron neutron capture therapy (BNCT) is a binary radiotherapy combining biochemical
targeting with neutron irradiation. However, monitoring the boron distribution is a …
targeting with neutron irradiation. However, monitoring the boron distribution is a …
Assessment of long-term risks of secondary cancer in paediatric patients with brain tumours after boron neutron capture therapy
This study firstly explored the risks of secondary cancer in healthy organs of Chinese
paediatric patients with brain tumours after boron neutron capture therapy (BNCT). Three …
paediatric patients with brain tumours after boron neutron capture therapy (BNCT). Three …
Dosimetric impact of respiratory motion during boron neutron capture therapy for lung cancer
Lung cancer is one of the cancers with high morbidity and mortality. Boron neutron capture
therapy (BNCT) has attracted researchers' attention in recent years because of its unique …
therapy (BNCT) has attracted researchers' attention in recent years because of its unique …
[HTML][HTML] GEANT4 Simulation of Photoneutron Spectrum from Medical Linear Accelerator
A Chernyaev, M Belikhin, E Lykova… - Quantum Beam …, 2023 - mdpi.com
Photons with energy totaling more than 10 MeV provide efficient treatment for deeply seated
tumors but interact with the nuclei of high-Z materials constituting a head of the linac. These …
tumors but interact with the nuclei of high-Z materials constituting a head of the linac. These …
Changes of the linear energy transfer (LET) and beam width of therapeutic carbon ion beam in density heterogeneous phantoms
S Yang, J Zhao, W Zhuo, H Shen… - Journal of Radiological …, 2022 - iopscience.iop.org
This work aims to investigate the changes in the linear energy transfer (LET) spectra
distribution and the beam spot width of a therapeutic carbon ion beam in density …
distribution and the beam spot width of a therapeutic carbon ion beam in density …
A significant review on beam optimization for boron neutron capture therapy
S Shalbi, N Sazali, WNW Salleh - IOP Conference Series …, 2020 - iopscience.iop.org
The thermal column at the TRIGA PUSPATI (RTP) research reactor can produce thermal
neutron. However, the optimization on the thermal neutron flux produced should be …
neutron. However, the optimization on the thermal neutron flux produced should be …
Implementation of Monte Carlo based PET verification of ion beam delivery into a TPS
P Yepes, Z Shen, MF Moyers, Q Wang… - Radiation Medicine …, 2022 - mednexus.org
Objective: To develop and implement an ion beam teletherapy verification system based
upon simulations of induced radioactivity and comparison with patient positron emission …
upon simulations of induced radioactivity and comparison with patient positron emission …
[HTML][HTML] Construction of voxel-based Portunus haanii phantom and its absorbed fractions and specific absorbed fractions calculation based on Monte Carlo …
Y Zhang, C Gong, C Guo, P Wang, W Wang… - Radiation Medicine and …, 2023 - Elsevier
Objective To build the database of the absorbed fractions (AFs) and specific absorbed
fractions (SAFs), in order to accurately assess the internal radiation dose in non-human …
fractions (SAFs), in order to accurately assess the internal radiation dose in non-human …