Monte-Carlo techniques for radiotherapy applications I: Introduction and overview of the different Monte-Carlo codes

AL Fielding - Journal of Radiotherapy in Practice, 2023 - cambridge.org
Introduction: The dose calculation plays a crucial role in many aspects of contemporary
clinical radiotherapy treatment planning process. It therefore goes without saying that the …

[HTML][HTML] Complete patient exposure during paediatric brain cancer treatment for photon and proton therapy techniques including imaging procedures

M de Saint-Hubert, G Boissonnat, U Schneider… - Frontiers in …, 2023 - frontiersin.org
Background In radiotherapy, especially when treating children, minimising exposure of
healthy tissue can prevent the development of adverse outcomes, including second cancers …

[HTML][HTML] Experimental validation of an analytical program and a Monte Carlo simulation for the computation of the far out-of-field dose in external beam photon therapy …

M De Saint-Hubert, F Suesselbeck, F Vasi… - Frontiers in …, 2022 - frontiersin.org
Background The out-of-the-field absorbed dose affects the probability of primary second
radiation-induced cancers. This is particularly relevant in the case of pediatric treatments …

Monte Carlo-based independent dose verification of radiosurgery HyperArc plans

JF Calvo-Ortega, S Moragues-Femenía, C Laosa-Bello… - Physica Medica, 2022 - Elsevier
Purpose To investigate the feasibility of using the free PRIMO Monte Carlo software for
independent dose check of cranial SRS plans designed with the Varian HyperArc (HA) …

PenRed: An extensible and parallel Monte-Carlo framework for radiation transport based on PENELOPE

V Giménez-Alventosa, VG Gómez, S Oliver - Computer Physics …, 2021 - Elsevier
Monte Carlo methods provide detailed and accurate results for radiation transport
simulations. Unfortunately, the high computational cost of these methods limits its usage in …

[HTML][HTML] MLC parameters from static fields to VMAT plans: an evaluation in a RT-dedicated MC environment (PRIMO)

L Paganini, G Reggiori, A Stravato, V Palumbo… - Radiation …, 2019 - Springer
Background PRIMO is a graphical environment based on PENELOPE Monte Carlo (MC)
simulation of radiotherapy beams able to compute dose distribution in patients, from plans …

Geometrical source modeling of 6MV flattening-filter-free (FFF) beam from TrueBeam linear accelerator and its commissioning validation using Monte Carlo simulation …

R Shende, SJ Dhoble, G Gupta - Radiation Physics and Chemistry, 2022 - Elsevier
Purpose To study geometrical source modeling of 6 MV flattening-filter-free (FFF) beam from
TrueBeam linear accelerator and its commissioning validation using Monte Carlo simulation …

[HTML][HTML] Treatment verification using Varian's dynalog files in the Monte Carlo system PRIMO

M Rodriguez, L Brualla - Radiation Oncology, 2019 - Springer
Background The PRIMO system is a computer software that allows the Monte Carlo
simulation of linear accelerators and the estimation of the subsequent absorbed dose …

Monte Carlo simulation of conical collimators for stereotactic radiosurgery with a 6 MV flattening‐filter‐free photon beam

M Hermida‐López, D Sánchez‐Artuñedo… - Medical …, 2021 - Wiley Online Library
Purpose Conical collimators, or cones, are tertiary collimators that attach to a radiotherapy
linac and are suited for the stereotactic radiosurgery treatment of small brain lesions. The …

[HTML][HTML] Monte Carlo simulation of the Varian TrueBeam flattened-filtered beams using a surrogate geometry in PRIMO

M Rodriguez, J Sempau, L Brualla - Radiation oncology, 2024 - Springer
Abstract Background Monte Carlo simulation of radiation transport for medical linear
accelerators (linacs) requires accurate knowledge of the geometrical description of the linac …