Using anatomy-based fitting to reduce frequency-to-place mismatch in experienced bilateral cochlear implant users: A promising concept

A Kurz, D Herrmann, R Hagen, K Rak - Journal of Personalized Medicine, 2023 - mdpi.com
Fitting cochlear implant (CI) users can be challenging. Anatomy-based fitting (ABF) maps
may have the potential to lead to better objective and subjective outcomes than conventional …

New Medical Device and Therapeutic Approvals in Otolaryngology: State of the Art Review of 2022

FM Wu, D Gorelik, MJ Brenner, M Takashima… - OTO …, 2024 - Wiley Online Library
Objective To review new drugs and devices relevant to otolaryngology approved by the
Food and Drug Administration (FDA) in 2022. Data Sources Publicly available FDA data on …

Comprehensive literature review on the application of the otological surgical planning software OTOPLAN® for cochlear implantation

FT Müller-Graff, B Spahn, DP Herrmann, A Kurz… - HNO, 2024 - Springer
Background The size of the human cochlear, measured by the diameter of the basal turn,
varies between 7 and 11 mm. For hearing rehabilitation with cochlear implants (CI), the size …

The Photon-Counting CT Enters the Field of Cochlear Implantation: Comparison to Angiography DynaCT and Conventional Multislice CT

K Rak, B Spahn, FT Müller-Graff, J Engert… - Otology & …, 2024 - journals.lww.com
Methods Ten human fresh-frozen petrous bone specimens were examined with a first-
generation PCCT. A clinically applicable radiation dose of 27.1 mGy was used. Scans were …

Accuracy of Preoperative Cochlear Duct Length Estimation and Angular Insertion Depth Prediction

T Breitsprecher, R Mlynski, C Völter… - Otology & …, 2023 - journals.lww.com
Objective In cochlear implantation with flexible lateral wall electrodes, a cochlear coverage
of 70% to 80% is assumed to yield an optimal speech perception. Therefore, fitting the …

Evaluation of a Radiological Tool for Semiautomatic Scalar Translocation Detection After Cochlear Implantation

SRS Arends, JJ Briaire, S Geiger… - Otology & …, 2023 - journals.lww.com
Main Outcome Measures The tool's scalar position assessments were compared with
manual ones by calculating intraclass coefficient (ICC) for individual contacts and sensitivity …

Umfassender Literaturüberblick über die Anwendung der otologisch-chirurgischen Planungssoftware OTOPLAN® bei der Cochleaimplantation

FT Müller-Graff, B Spahn, DP Herrmann, A Kurz… - HNO, 2024 - Springer
Zusammenfassung Hintergrund Die Größe der menschlichen Cochlea, gemessen am
Durchmesser der Basalwindung, schwankt zwischen 7 und 11 mm. Im Rahmen einer …

Development of an Algorithm for Correct Placement of the Basal Electrode Contact in the Context of Anatomy-Based Cochlear Implantation: A Proof of Concept

JEDBA Kurza, RHT Neunb, SZK Raka - 2024 - karger.com
Background: Correct individual tonotopic frequency stimulation of the cochlea plays an
important role in the further development of anatomy-based cochlear implantation. In this …