Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of Hp (3) monitoring. A 2015 review

E Carinou, P Ferrari, OC Bjelac… - Journal of …, 2015 - iopscience.iop.org
A thorough literature review about the current situation on the implementation of eye lens
monitoring has been performed in order to provide recommendations regarding dosemeter …

Review of x-ray exposure and safety issues arising from ultra-short pulse laser material processing

H Legall, J Bonse, J Krüger - Journal of Radiological Protection, 2021 - iopscience.iop.org
Laser processing with ultra-short laser pulses enables machining of materials with high
accuracy and throughput. The development of novel laser technologies with laser pulse …

Conversion coefficients for radiological protection quantities for external radiation exposures

N Petoussi-Henss, WE Bolch… - Annals of the …, 2010 - journals.sagepub.com
Conversion Coefficients for Radiological Protection Quantities for External Radiation
Exposures - CH Clement, N. Petoussi-Henss, WE Bolch, KF Eckerman, A. Endo, N. Hertel, J …

[HTML][HTML] The radiation field in the Gamma Irradiation Facility GIF++ at CERN

D Pfeiffer, G Gorine, H Reithler, B Biskup, A Day… - Nuclear Instruments and …, 2017 - Elsevier
The high-luminosity LHC (HL-LHC) upgrade is setting now a new challenge for particle
detector technologies. The increase in luminosity will produce a particle background in the …

[HTML][HTML] X-ray emission as a potential hazard during ultrashort pulse laser material processing

H Legall, C Schwanke, S Pentzien, G Dittmar, J Bonse… - Applied physics A, 2018 - Springer
In laser machining with ultrashort laser pulses unwanted X-ray radiation in the keV range
can be generated when a critical laser intensity is exceeded. Even if the emitted X-ray dose …

[HTML][HTML] X-ray radiation protection aspects during ultrashort laser processing

H Legall, C Schwanke, J Bonse… - Journal of Laser …, 2020 - pubs.aip.org
Ultrashort pulse laser processing of materials allows for precise machining with high
accuracy. By increasing the repetition rate to several 100kHz, laser machining becomes …

[HTML][HTML] Conversion coefficients calculation of mono-energetic photons from air-kerma using Monte Carlo and analytical methods

H Al Kanti, O El Hajjaji, T El Bardouni, H Boukhal… - Journal of King Saud …, 2020 - Elsevier
This study is aimed to calculate the conversion coefficients H∗(10)/Φ form air-kerma for
beams of mono-energetic photons, which incident on ICRU sphere diameter 30 cm of ICRU …

[HTML][HTML] Eye lens dosimetry in Canadian CANDU nuclear power plants based on operational dosimetric quantities Hp (10) and Hp (0.07)

J Atanackovic, AR Hanu, SH Byun - Applied Radiation and Isotopes, 2021 - Elsevier
In this article, we present a methodology for performing eye lens dosimetry in CANDU
nuclear power plants using an existing and highly accurate Harshaw 4-element TLD-700 …

Extensive study of radiation dose on human body at aviation altitude through Monte Carlo simulation

A Roy, R Sarkar, C Lee - Life Sciences in Space Research, 2021 - Elsevier
The diverse near-Earth radiation environment due to cosmic rays and solar radiation has
direct impact on human civilization. In the present and upcoming era of increasing air …

An analytical fit and EGSnrc code (MC) calculations of personal dose equivalent conversion coefficients for mono-energetic electrons

H Al Kanti, O El Hajjaji, T El Bardouni… - Applied Radiation and …, 2019 - Elsevier
This study aims for calculating a new set of the personal dose equivalent conversion
coefficients H p (d)/Φ when d= 0.07, 3, and 10 mm, for mono-energetic electron beams …