A generic small-signal stability criterion of DC distribution power system: Bus node impedance criterion (BNIC)
The dc distribution power system has drawn widespread attention and rapidly developed in
recent years; however, its stability issue is one of the urgent challenges, requiring much …
recent years; however, its stability issue is one of the urgent challenges, requiring much …
Oscillation propagation analysis of hybrid AC/DC grids with high penetration renewables
The high penetration of renewables has sparked new oscillatory concerns in hybrid AC/DC
grids. Knowledge of the oscillation regarding its source and propagation mechanism, is …
grids. Knowledge of the oscillation regarding its source and propagation mechanism, is …
Small-signal stability analysis and criterion of triple-stage cascaded DC system
Two individually stable converters are well-known preconditions for discussing the stability
of a two-stage cascaded system. However, for a multistage cascaded system, the …
of a two-stage cascaded system. However, for a multistage cascaded system, the …
Two-port characterization and transfer immittances of AC-DC converters—Part I: Modeling
J Sun - IEEE Open Journal of Power Electronics, 2021 - ieeexplore.ieee.org
This two-part paper presents a general method to model three-phase ac-dc converters in the
frequency domain for power system stability studies. In the developed approach, an ac-dc …
frequency domain for power system stability studies. In the developed approach, an ac-dc …
Harmonic stability assessment of multiterminal DC (MTDC) systems based on the hybrid AC/DC admittance model and determinant-based GNC
H Zhang, X Wang… - … on Power Electronics, 2021 - ieeexplore.ieee.org
Growing concerns with the harmonic oscillation phenomenon of multiterminal DC (MTDC)
systems calls for appropriate harmonic stability analysis methods. However, the …
systems calls for appropriate harmonic stability analysis methods. However, the …
Low-frequency oscillation analysis of VSM-based VSC-HVDC systems based on the five-dimensional impedance stability criterion
J Guo, Y Chen, S Liao, W Wu, X Wang… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
Virtual synchronous machine (VSM) based high voltage dc systems enhance the inertia of
the power system. However, the dynamic interactions between the VSM-based rectifier …
the power system. However, the dynamic interactions between the VSM-based rectifier …
Stability analysis of a grid-tied interlinking converter system with the hybrid AC/DC admittance model and determinant-based GNC
H Zhang, M Mehrabankhomartash… - … on Power Delivery, 2021 - ieeexplore.ieee.org
This paper is mainly focused on the stability-related issues of a grid-tied interlinking
converter system. First, hybrid AC/DC admittance characteristics of an interlinking converter …
converter system. First, hybrid AC/DC admittance characteristics of an interlinking converter …
A combined bus port impedance based stability criterion for DC distribution power systems
The impedance-based criteria are well known to assess the stability of DC systems by
impedance measurement method. However, these criteria apply to the DC systems with the …
impedance measurement method. However, these criteria apply to the DC systems with the …
System harmonic stability analysis of grid-tied interlinking converters operating under AC voltage control mode
H Zhang, M Saeedifard, X Wang… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
The hybrid AC/DC admittance of interlinking converters operating under AC voltage control
mode may contain right half-plane (RHP) pole (s), and thus, the existing harmonic stability …
mode may contain right half-plane (RHP) pole (s), and thus, the existing harmonic stability …
A Sequential SISO Stability Analysis Model for Grid-connected Converters by Considering the Impact of Power Flow Direction
H Zhang, M Saeedifard, X Wang… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
For grid-connected converters operating under nonunity power factor, their admittances
become off-diagonal due to emerging of the coupling admittances. Consequently, the grid …
become off-diagonal due to emerging of the coupling admittances. Consequently, the grid …