[PDF][PDF] 光纤耦合GAGG_Ce 型X 射线探测器高分辨成像

安康, 李汶芳, 段晓礁, 吴石琳, 周日峰, 王珏 - Acta Optica Sinica, 2022 - researching.cn
摘要闪烁屏信号串扰是影响X 射线探测器空间分辨率的主要因素, 基于点扩散函数理论对光纤
耦合GAGG_Ce 单晶闪烁屏型CCD/CMOS 探测器的空间分辨率进行了研究. 利用蒙特卡罗程序 …

Potent immunomodulatory effects of an anti-CEA-IL-2 immunocytokine on tumor therapy and effects of stereotactic radiation

M Kujawski, M Sherman, S Hui, D Zuro, WH Lee… - …, 2020 - Taylor & Francis
While anti-CEA antibodies have no direct effect on CEA-positive tumors, they can be used to
direct potent anti-tumor effects as an antibody-IL-2 fusion protein (immunocytokine, ICK) …

An implementation to read and write IAEA phase-space files in GEANT4-based simulations

MA Cortés-Giraldo, JM Quesada… - … journal of radiation …, 2012 - Taylor & Francis
Purpose: To develop a stand-alone code to make any application coded with the GEANT4
(GEometry ANd Tracking, version 4) toolkit capable of reading and writing phase-space …

Monte Carlo simulation of linac using PRIMO

Y Li, X Sun, Y Liang, Y Hu, C Liu - Radiation Oncology, 2022 - Springer
Abstract Background Monte Carlo simulation is considered as the most accurate method for
dose calculation in radiotherapy. PRIMO is a Monte-Carlo program with a user-friendly …

Out-of-field dose calculation by a commercial treatment planning system and comparison by monte carlo simulation for varian TrueBeam®

NS Shine, R Paramu, M Gopinath… - Journal of medical …, 2019 - journals.lww.com
Purpose: The calculation accuracy of treatment planning systems (TPSs) drops drastically
when the points outside the field edges are considered. The real accuracy of a TPS and …

Accuracy of the electron transport in mcnp5 and its suitability for ionization chamber response simulations: A comparison with the egsnrc and penelope codes

H Koivunoro, T Siiskonen, P Kotiluoto… - Medical …, 2012 - Wiley Online Library
Purpose: In this work, accuracy of themcnp5 code in the electron transport calculations and
its suitability for ionization chamber (IC) response simulations in photon beams are studied …

Murine-specific internal dosimetry for preclinical investigations of imaging and therapeutic agents

B Bednarz, J Grudzinski, I Marsh, A Besemer… - Health …, 2018 - journals.lww.com
There is a growing need to estimate the absorbed dose to small animals from preclinical
investigations involving diagnostic and therapeutic radiopharmaceuticals. This paper …

Comprehensive evaluation and clinical implementation of commercially available Monte Carlo dose calculation algorithm

A Zhang, N Wen, T Nurushev… - Journal of Applied …, 2013 - Wiley Online Library
A commercial electron Monte Carlo (eMC) dose calculation algorithm has become available
in Eclipse treatment planning system. The purpose of this work was to evaluate the eMC …

Geant4 electromagnetic physics: improving simulation performance and accuracy

VN Ivanchenko, S Incerti… - … MC 2013-Joint …, 2014 - sna-and-mc-2013-proceedings …
The most recent upgrades of the electromagnetic (EM) physics “standard” and “low energy”
sub-libraries of the general purpose Geant4 Monte Carlo simulation toolkit are described …

Uncertainties in Monte Carlo-based absorbed dose calculations for an experimental benchmark

F Renner, J Wulff, RP Kapsch… - Physics in Medicine & …, 2015 - iopscience.iop.org
There is a need to verify the accuracy of general purpose Monte Carlo codes like EGSnrc,
which are commonly employed for investigations of dosimetric problems in radiation …