ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: summary article: a report of the American College of Cardiology/American …

Committee Members, MD Cheitlin, WF Armstrong… - Circulation, 2003 - Am Heart Assoc
recommendations. A new section on the use of intraoperative transesophageal
echocardiography (TEE) is being added to update the guidelines published by the American …

Use of real time three-dimensional transesophageal echocardiography in intracardiac catheter based interventions

G Perk, RM Lang, MA Garcia-Fernandez… - Journal of the American …, 2009 - Elsevier
BACKGROUND: Real-time three-dimensional (RT3D) echocardiography is a recently
developed technique that is being increasingly used in echocardiography laboratories. Over …

Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders

J Masura, P Gavora, T Podnar - Journal of the American College of …, 2005 - jacc.org
Objectives: The aim of this study was to assess long-term results of percutaneous closure of
secundum-type atrial septal defect (ASD II) using Amplatzer septal occluders (ASO) …

Relative risk factors for cardiac erosion following transcatheter closure of atrial septal defects: a case–control study

DB McElhinney, MD Quartermain, D Kenny… - Circulation, 2016 - Am Heart Assoc
Background—Transcatheter closure of secundum atrial septal defects (ASD) using the
Amplatzer septal occluder is generally safe and effective, but erosion into the pericardial …

A randomized trial of aspirin on the risk of embolic events in patients with infective endocarditis

KL Chan, JG Dumesnil, B Cujec, AJ Sanfilippo… - Journal of the American …, 2003 - jacc.org
Objectives: This study examined the effect of aspirin on the risk of embolic events in infective
endocarditis (IE). Background: Embolism is a major complication of IE, and studies in animal …

Closure of secundum atrial septal defects with the Amplatzer septal occluder device: techniques and problems

RW Harper, PM Mottram… - Catheterization and …, 2002 - Wiley Online Library
Percutaneous transvenous closure of atrial septal defects (ASDs) has become feasible in
recent years, as later‐generation devices have largely overcome initial difficulties in device …

Closure of secundum atrial septal defects with the AMPLATZER septal occluder: a prospective, multicenter, post-approval study

DR Turner, CY Owada, CJ Sang Jr… - Circulation …, 2017 - Am Heart Assoc
Background—Prospective data on the medium-term safety and effectiveness of the
AMPLATZER Septal Occluder in clinical practice are not available. The objective of this …

Treatment of isolated secundum atrial septal defects: impact of age and defect morphology in 1,013 consecutive patients

G Butera, E Romagnoli, M Carminati, M Chessa… - American heart …, 2008 - Elsevier
BACKGROUND: Percutaneous closure of atrial septal defect (ASD) is a valid alternative to
surgical approach. Current device has significantly improved the success rate also in …

Echocardiographic predictors of cardiac erosion after Amplatzer septal occluder placement

Z Amin - Catheterization and Cardiovascular Interventions, 2014 - Wiley Online Library
The risk of erosion after Amplatzer septal occluder (ASO) device placement in atrial septal
defects is well described. Aortic rim deficiency and use of over‐sized device increase the …

Clinical update: atrial septal defect in adults

JB Lindsey, LD Hillis - The Lancet, 2007 - thelancet.com
Atrial septal defect (ASD) accounts for 25–30% of congenital heart defects that are
diagnosed in adult hood. ASDs are classified according to location in the interatrial septum …