Echocardiographic guidance of catheter-based treatments of atrial septal defect: transesophageal echocardiography remains the gold standard

CS Kleinman - Pediatric cardiology, 2005 - Springer
The availability of echocardiographic imaging to the catheterization laboratory has been
recognized as an essential component of every congenital heart program for almost 30 …

Supplementing transesophageal echocardiography with transthoracic echocardiography for monitoring transcatheter closure of atrial septal defects with attenuated …

SM Lin, SK Tsai, JK Wang, YY Han, W Jean… - Anesthesia & …, 2003 - journals.lww.com
The use of transesophageal echocardiography (TEE) for guidance of transcatheter closure
of secundum-type atrial septal defect (ASD) is increasingly becoming a routine procedure …

Feasibility of transcatheter closure of large secundum atrial septal defect with absent superior or inferior rim

H Abdulwahab, MR Husain… - Journal of Interventional …, 2022 - Wiley Online Library
Introduction. Surgical closure of a large secundum atrial septal defect (ASD) with an absent
superior or inferior rim is the standard method of management, but transcatheter closure of …

Atrial Septal Occluder Device Embolization to an Iliac Artery: A Case Highlighting the Utility of Three‐Dimensional Transesophageal Echocardiography during …

J Wei, MC Hsiung, SK Tsai, WH Yin, CH Ou… - …, 2012 - Wiley Online Library
Percutaneous closure of secundum atrial defects has become an accepted treatment in part
because it is minimally invasive and relatively low risk. Despite recent advances in …

[HTML][HTML] Transcatheter closure of multiple atrial septal defects with the amplatzer device

MJ Cho, J Song, SJ Kim, EY Choi… - Korean Circulation …, 2011 - synapse.koreamed.org
Percutaneous device occlusion of secundum atrial septal defect (ASD) has become an
accepted alternative to surgical repair. A variety of devices have been used successfully …

[PDF][PDF] Real-time three-dimensional transesophageal echocardiography is useful for percutaneous closure of multiple secundum atrial septal defects

C Zhang, Z Li, J Xu - Hellenic J Cardiol, 2014 - hellenicjcardiol.org
Results: The custom-made atrial septal occluders were successfully implanted in 36 patients
under RT-3DTEE guidance. Twenty-seven patients were implanted with two devices and 9 …

Transcatheter closure of fenestrated atrial septal aneurysm in children: Feasibility and long‐term results

HT Mahmoud, G Gaio, M Giordano… - Catheterization and …, 2022 - Wiley Online Library
Background To date, extensive experience in transcatheter closure of fenestrated atrial
septal aneurysm (ASA) in the pediatric population is limited. Methods To report on …

[HTML][HTML] Effectiveness of the Amplatzer™ device for transcatheter closure of an ostium secundum atrial septal defect

CO Cardoso, RI Rossi Filho, PR Machado… - Arquivos brasileiros de …, 2007 - SciELO Brasil
OBJETIVO: Avaliar a efetividade da prótese de Amplatzer® para tratamento de
comunicação interatrial tipo ostium secundum (CIA OS). MÉTODOS: Estudo de coorte …

[HTML][HTML] Fenestrated atrial septal defect percutaneously occluded by a single device: procedural and financial considerations

R Tal, Q Dahud, A Lorber - Cardiology and therapy, 2013 - Springer
A 45-year-old patient presented with a cerebrovascular attack and was subsequently found
to have a multi-fenestrated atrial septal defect. Various therapeutic options for percutaneous …

Transcatheter closure of atrial septal defect with deficient posterior-inferior or inferior vena cava rim under echocardiography only: a feasibility and safety analysis

LL Huang, J Wu, M Chen, CL Jiang, DC Zeng… - Cardiology in the …, 2022 - cambridge.org
Background: The safe closure of atrial septal defect with deficient posterior-inferior or inferior
vena cava rim is a controversial issue. Few studies have been conducted on the closure of …