Measurement of tumor oxygenation: a comparison between polarographic needle electrodes and a time-resolved luminescence-based optical sensor

DR Collingridge, WK Young, B Vojnovic… - Radiation …, 1997 - meridian.allenpress.com
A novel oxygen sensor which does not rely on electrochemical reduction has been used to
measure the oxygenation of the murine sarcoma F in a comparative study with an existing …

In vivo measurement of tissue oxygenation by time-resolved luminescence spectroscopy: advantageous properties of dichlorotris(1, 10-phenanthroline)-ruthenium(II) …

V Huntosova, S Gay… - … of biomedical optics, 2014 - spiedigitallibrary.org
Measuring tissue oxygenation in vivo is of interest in fundamental biological as well as
medical applications. One minimally invasive approach to assess the oxygen partial …

Luminescence-Based Oxygen Sensors: ReL(CO)3Cl and ReL(CO)3CN Complexes on Copolymer Supports

KA Kneas, W Xu, JN Demas, BA DeGraff… - Journal of …, 1998 - Springer
A new class of luminescent rhenium complexes has been tested as oxygen sensors based
on luminescent quenching. ReL (CO) 3 Cl and ReL (CO) 3 CN (L= 2, 2′-bipyridine or 1, 10 …

Oxygen Sensors Based on a Quenching of Tris-(4, 7-diphenyl-1, 10-phenanthroline) ruthenium (II) in Fluorinated Polymers

AM Morin, W Xu, JN Demas, BA DeGraff - Journal of Fluorescence, 2000 - Springer
Luminescence quenching of Ru (II) complexes by oxygen has proved a powerful method of
quantitative oxygen analysis. It has become clear that the polymer support for the sensor …

Brain Tissue and Sagittal Sinus pO2 Measurements Using the Lifetimes of Oxygen-Quenched Luminescence of a Ruthenium Compound

CI Nwaigwe, MA Roche, O Grinberg… - Oxygen Transport to Tissue …, 2003 - Springer
The study was done to assess the performance of a system that measures the partial
pressures of oxygen (pO 2) from the lifetimes of oxygen-quenched luminescence of …

Influence of the precursor nature and deposition mode on the oxygen sensing properties of Ru (II) complex immobilized in a SiO2-based matrix

S Anastasova, M Milanova, S Rangelov… - Journal of non …, 2008 - Elsevier
Films are deposited by dip-or spin-coating in gels produced from tetraethoxysilane (TEOS),
octyltriethoxysilane (OtEOS) or mixtures of TEOS and OtEOS (mole ratio1: 1) as well as …

Fiber optic sensor for oxygen measurement in tumors

WK Young, B Vojnovic… - Medical and Fiber Optic …, 1995 - spiedigitallibrary.org
A prototype fiber optic fluorosensor for measuring low (radiobiologically relevant) levels of
oxygen is described. The fluorescence of an excited fluorophor immobilized in a polymer at …