Characterization and Use of a Fiber Optic Sensor Based on PAH/SiO2 Film for Humidity Sensing in Ventilator Care Equipment

FU Hernandez, SP Morgan… - IEEE Transactions …, 2016 - ieeexplore.ieee.org
Objective: To develop a compact probe that can be used to monitor humidity in ventilator
care equipment. A mesoporous film of alternate layers of Poly (allylamine …

Assessment of tracheal temperature and humidity in laryngectomized individuals and the influence of a heat and moisture exchanger on tracheal climate

JK Zuur, SH Muller, A Vincent… - Head & Neck …, 2008 - Wiley Online Library
Background The beneficial function of heat and moisture exchangers (HMEs) is undisputed,
but knowledge of their effects on intra‐airway temperature and humidity is scarce. The aim of …

Effects of heat and moisture exchangers on tracheal mucociliary clearance in laryngectomized patients: a multi-center case–control study

C Van den Boer, SH Muller, V van der Noort… - European Archives of …, 2015 - Springer
After total laryngectomy, inspired air is no longer optimally conditioned by the upper airways.
Impaired mucociliary clearance and histological changes of respiratory epithelium, such as …

Understanding and predicting the performance of passive heat and moisture exchangers using a numerical model

M Leemans, MJA van Alphen, W Vallenduuk… - Head & …, 2023 - Wiley Online Library
Background To improve the understanding of the thermodynamics and performance of small
passive hygroscopic Heat and Moisture Exchangers (HMEs), a computer model simulating …

Ex vivo assessment and validation of water exchange performance of 23 heat and moisture exchangers for laryngectomized patients

C van den Boer, SH Muller, AD Vincent… - Respiratory …, 2014 - rc.rcjournal.com
BACKGROUND: Breathing through a tracheostoma results in insufficient warming and
humidification of the inspired air. This loss of air conditioning, especially humidification, can …

Influence of breathing resistance of heat and moisture exchangers on tracheal climate and breathing pattern in laryngectomized individuals

RJ Scheenstra, SH Muller, A Vincent… - Head & …, 2010 - Wiley Online Library
Background. The aim of this study was to determine the influence of breathing resistance of
heat and moisture exchangers (HMEs) on endotracheal climate and breathing pattern …

Effect of cloth stoma covers on tracheal climate of laryngectomy patients

G Quail, JJ Fagan, O Raynham, H Krynauw… - Head & …, 2016 - Wiley Online Library
Background The purpose of this study was to evaluate the efficacy of cloth stoma covers
(bibs) to compensate for breathing unconditioned air after laryngectomy and loss of heat …

The influence of a heat and moisture exchanger on tracheal climate in a cold environment

JK Zuur, SH Muller, A Vincent, M Sinaasappel… - Medical engineering & …, 2009 - Elsevier
OBJECTIVE: The incidence of pulmonary complaints, severe tracheitis and lung function
deterioration is increased during wintertime in laryngectomized individuals. We analyzed …

Endotracheal temperature and humidity measurements in laryngectomized patients: intra-and inter-patient variability

RJ Scheenstra, SH Muller, A Vincent… - Medical & biological …, 2009 - Springer
This study assesses intra-and inter-patient variability in endotracheal climate (temperature
and humidity) and effects of heat and moister exchangers (HME) in 16 laryngectomized …

A novel, simplified ex vivo method for measuring water exchange performance of heat and moisture exchangers for tracheostomy application

C van den Boer, SH Muller, AD Vincent… - Respiratory …, 2013 - rc.rcjournal.com
BACKGROUND: Breathing through a tracheostomy results in insufficient warming and
humidification of inspired air. This loss of air-conditioning can be partially compensated for …