Clinical Outcomes of Non-Atrial Fibrillation Bradyarrhythmias Treated With a Ventricular Demand Leadless Pacemaker Compared With an Atrioventricular …

K Sasaki, D Togashi, I Nakajima, T Suchi… - Circulation …, 2022 - jstage.jst.go.jp
Background: Implanting a ventricular demand leadless pacemaker (VVI-LPM) for patients
with non-atrial fibrillation (AF) bradyarrhythmias such as sick sinus syndrome (SSS) or high …

Safety and feasibility of atrial fibrillation ablation after left atrial appendage closure: A singlecenter experience of the left atrial appendage closure first strategy

R Chatani, S Kubo, H Tasaka, A Sakata… - Journal of …, 2024 - Wiley Online Library
Background Patients with atrial fibrillation (AF) who are not suitable for longterm
anticoagulant therapy undergo percutaneous left atrial appendage closure (LAAC). The …

Primary results from the Japanese Heart Failure and sudden cardiac death Prevention Trial (HINODE)

K Aonuma, K Ando, K Kusano, T Asai, K Inoue… - ESC heart …, 2022 - Wiley Online Library
Aims The HINODE study aimed to analyse rates of mortality, appropriately treated ventricular
arrhythmias (VA), and heart failure in Japanese patients and compared with those in …

Rationale and design of the NEO-NORMAL-AF study examination of the usefulness of implantable loop recorder for arrhythmia detection including atrial fibrillation in …

J Sugiura, S Kasama, T Ueda, T Nishida, H Kawata… - Open …, 2023 - openheart.bmj.com
Introduction The incidence of arrhythmia in heart failure with non-reduced ejection fraction
(HFnon-rEF) in patients who have a history of hospitalisation is unclear. The aim of this study …

Clinical implication of left atrial appendage emptying velocity in thoracoscopic ablation of atrial fibrillation

J Kim, M Bak, SJ Park, DS Jeong, S Chung… - Circulation …, 2023 - jstage.jst.go.jp
Background: There are limited data about predictors of atrial fibrillation (AF) recurrence after
totally thoracoscopic ablation (TTA). This study investigated the clinical implication of left …

Low-Voltage-Area Ablation in Paroxysmal Atrial Fibrillation―Extended Follow-up Results of the VOLCANO Trial―

M Masuda, M Asai, O Iida, S Okamoto, T Ishihara… - Circulation …, 2022 - jstage.jst.go.jp
Background: The randomized controlled VOLCANO trial demonstrated comparable 1-year
rhythm outcomes between patients with and without ablation targeting low-voltage areas …

Significance of effective cardiac resynchronization therapy pacing for clinical responses: an analysis based on the effective cardiac resynchronization therapy …

S Oka, N Ueda, K Ishibashi, T Noda, Y Miyazaki… - Heart Rhythm, 2023 - Elsevier
Background High percent ventricular pacing maximizes cardiac resynchronization therapy
(CRT) response. An effective CRT algorithm classifies each left ventricular (LV) pace as …

Urinary isoxanthopterin as a novel predictor following catheter ablation for atrial fibrillation

T Koi, N Kataoka, K Uchida, T Imamura… - Journal of …, 2023 - Wiley Online Library
Background Oxidative stress is associated with atrial fibrillation recurrence following
catheter ablation. Urinary isoxanthopterin (UIXP) is one of the noninvasive markers which …

A novel practical algorithm using machine learning to differentiate outflow tract ventricular arrhythmia origins

M Shimojo, Y Inden, S Yanagisawa… - Journal of …, 2023 - Wiley Online Library
Introduction Diagnosis of outflow tract ventricular arrhythmia (OTVA) localization by an
electrocardiographic complex is key to successful catheter ablation for OTVA. However …

Long P-wave duration immediately after pulmonary vein isolation on radiofrequency catheter ablation for atrial fibrillation predicts clinical recurrence: correlation with …

S Ohguchi, Y Inden, S Yanagisawa, T Shigematsu… - Heart and Vessels, 2022 - Springer
P-wave morphology reflects atrial remodeling and indicates prognosis after radiofrequency
catheter ablation (RFCA) for atrial fibrillation (AF). The impact of p-wave morphology after …