Mitral Valve and Tricuspid Valve Blood Flow: Accurate Quantification with 3D Velocity-encoded MR Imaging with Retrospective Valve Tracking1
JJM Westenberg, SD Roes, N Ajmone Marsan… - Radiology, 2008 - pubs.rsna.org
Purpose: To validate flow assessment performed with three-dimensional (3D) three-
directional velocity-encoded (VE) magnetic resonance (MR) imaging with retrospective …
directional velocity-encoded (VE) magnetic resonance (MR) imaging with retrospective …
Heart disease in the elderly
JY Wei, BJ Gersh - Current problems in cardiology, 1987 - Elsevier
As the number of individuals over age 65 years continues to increase, the elderly will
comprise an ever-growing portion of each physician's practice. While heart disease in the …
comprise an ever-growing portion of each physician's practice. While heart disease in the …
Impact of impinging wall jet on color Doppler quantification of mitral regurgitation.
CG Chen, JD Thomas, J Anconina, P Harrigan… - Circulation, 1991 - Am Heart Assoc
BACKGROUND In clinical color Doppler examinations, mitral regurgitant jets are often
observed to impinge on the left atrial wall immediately beyond the mitral valve. In …
observed to impinge on the left atrial wall immediately beyond the mitral valve. In …
Impact of atrial fibrillation on tricuspid and mitral annular dilatation and valvular regurgitation
X Zhou, Y Otsuji, S Yoshifuku, T Yuasa, H Zhang… - Circulation …, 2002 - jstage.jst.go.jp
To investigate the effects of atrial fibrillation (AF) on the mitral and tricuspid valves, the
corresponding annular dilatation and valvular regurgitation were compared with 2 …
corresponding annular dilatation and valvular regurgitation were compared with 2 …
Application of color Doppler flow mapping to calculate effective regurgitant orifice area. An in vitro study and initial clinical observations.
PM Vandervoort, JM Rivera, D Mele, IF Palacios… - Circulation, 1993 - Am Heart Assoc
BACKGROUND Analogous to stenotic valve area in the assessment of valvular stenosis,
regurgitant orifice area (ROA) represents a fundamental parameter to assess valvular …
regurgitant orifice area (ROA) represents a fundamental parameter to assess valvular …
Direct measurement of vena contracta area by real-time 3-dimensional echocardiography for assessing severity of mitral regurgitation
C Yosefy, J Hung, S Chua, M Vaturi, TT Ton-Nu… - The American journal of …, 2009 - Elsevier
We tested the hypothesis that the vena contracta (VC) cross-sectional area in patients with
mitral regurgitation (MR) can be reproducibly measured by real-time 3-dimensional (3D) …
mitral regurgitation (MR) can be reproducibly measured by real-time 3-dimensional (3D) …
Proximal flow convergence region as assessed by real-time 3-dimensional echocardiography: challenging the hemispheric assumption
OBJECTIVE: Traditionally, a hemispheric assumption for the proximal flow convergence
region (PFCR) is used when calculating mitral regurgitant (MR) effective orifice area …
region (PFCR) is used when calculating mitral regurgitant (MR) effective orifice area …
Echocardiography of the mitral valve
X Zeng, TC Tan, DM Dudzinski, J Hung - Progress in Cardiovascular …, 2014 - Elsevier
Echocardiography is the primary imaging modality for assessment of the mitral valve (MV). It
provides an accurate and non-invasive tool to assess the morphology, geometry and …
provides an accurate and non-invasive tool to assess the morphology, geometry and …
Quantification of mitral regurgitation by the proximal convergence method using transesophageal echocardiography: clinical validation of a geometric correction for …
M Pu, PM Vandervoort, BP Griffin, DY Leung… - Circulation, 1995 - Am Heart Assoc
Background Proximal flow convergence is a promising method to quantify mitral
regurgitation but may overestimate flow when the flow field is constrained. This has not been …
regurgitation but may overestimate flow when the flow field is constrained. This has not been …
Proximal jet size by doppler color flow mapping predicts severityof mitral regurgitation: Clinical studies
D Mele, P Vandervoort, I Palacios, JM Rivera… - Circulation, 1995 - Am Heart Assoc
Background Recent studies have shown that many instrument and physiological factors limit
the ability of color Doppler total jet area within the receiving chamber to predict the severity …
the ability of color Doppler total jet area within the receiving chamber to predict the severity …