Magnetic resonance-based thermometry during laser ablation on ex-vivo swine pancreas and liver

G Allegretti, P Saccomandi, F Giurazza… - Medical engineering & …, 2015 - Elsevier
Laser Ablation (LA) is a minimally-invasive procedure for tumor treatment. LA outcomes
depend on the heat distribution inside tissues and require accurate temperature …

Validating a simulation model for laser-induced thermotherapy using MR thermometry

F Hübner, S Blauth, C Leithäuser… - International Journal …, 2022 - Taylor & Francis
Objectives We want to investigate whether temperature measurements obtained from MR
thermometry are accurate and reliable enough to aid the development and validation of …

A thermometry software tool for monitoring laser-induced interstitial thermotherapy

B Bazrafshan, A Koujan, F Hübner… - Biomedical …, 2019 - degruyter.com
The purpose of this study was to develop a thermometry software tool for temperature
monitoring during laser-induced interstitial thermotherapy (LITT). C++ programming …

White paper: interventional MRI: current status and potential for development considering economic perspectives, part 2: liver and other applications in oncology

J Barkhausen, T Kahn, GA Krombach… - RöFo-Fortschritte auf …, 2017 - thieme-connect.com
Hintergrund Die interventionelle MRT mit den Vorteilen des hohen Weichteilkontrasts und
der Temperatursensitivität sowie der freien Wahl der Schichtebene bietet Eigenschaften, die …

Feasibility assessment of magnetic resonance-thermometry on pancreas undergoing laser ablation: Sensitivity analysis of three sequences

P Saccomandi, C Massaroni, S Silvestri, F Giurazza… - Measurement, 2016 - Elsevier
Laser ablation (LA) is a minimally invasive technique for the treatment of tumors as an
alternative to surgical resection. The light absorbed by tissue is converted into heat, and …

Effects of different 980‐nm diode laser parameters in hepatectomy

T Ma, YC Chai, HY Zhu, H Chen… - Lasers in Surgery …, 2019 - Wiley Online Library
Background and Objective Despite the successful application of laser in animal experiments
and clinics, the adjustment of laser parameters during surgery is still unclear. This study …

A dual-mode microwave applicator for liver tumor thermotherapy

C Reimann, M Schüßler, R Jakoby, B Bazrafshan… - Frequenz, 2018 - degruyter.com
The concept of a novel dual-mode microwave applicator for diagnosis and thermal ablation
treatment of tumorous tissue is presented in this paper. This approach is realized by …

Evolution of a theranostic applicator for microwave ablation treatment

C Hessinger, F Hübner, M Schüßler, M Paravicini… - Frequenz, 2022 - degruyter.com
The purpose of this work is to further develop a novel dual-mode microwave applicator for
diagnosis and thermal ablation treatment. The MR-compatible MW applicator enables …

MR thermometry analysis program for laser-or high-intensity focused ultrasound (HIFU)-induced heating at a clinical MR scanner

EJ Kim, K Jeong, SJ Oh, D Kim, EH Park… - Journal of the Korean …, 2014 - Springer
Magnetic resonance (MR) thermometry is a noninvasive method for monitoring local
temperature change during thermal therapy. In this study, a MR temperature analysis …

Non-invasive MR thermometry in liver undergoing laser ablation: multi-parameters analysis

P Saccomandi, E Magnoni, C Massaroni… - 2018 IEEE …, 2018 - ieeexplore.ieee.org
The aim of this work is to define suitable parameters to perform non-invasive magnetic
resonance (MR) thermometry during laser ablation (LA) on biological tissues. Fast MR scans …