[HTML][HTML] Analytic optimization of cantilevers for photoacoustic gas sensor with capacitive transduction
We propose a new concept of photoacoustic gas sensing based on capacitive transduction
which allows full integration while conserving the required characteristics of the sensor. For …
which allows full integration while conserving the required characteristics of the sensor. For …
Electrical capacitance tomography with differential sensor
In electrical capacitance tomography, capacitance changes are used to determine the
permittivity distribution in the imaging area. However, the changes are small compared with …
permittivity distribution in the imaging area. However, the changes are small compared with …
88-A 1-MHz Stray-Insensitive CMOS Current-Mode Interface IC for Differential Capacitive Sensors
The paper describes an innovative technique to implement a low-power high-speed CMOS
interface circuit for differential capacitive sensors. The proposed approach comprises a …
interface circuit for differential capacitive sensors. The proposed approach comprises a …
A current-mode, dual slope, integrated capacitance-to-pulse duration converter
A capacitance-to-pulse duration converter, specifically designed for interfacing capacitive
sensors, is presented. The operating principle is a double slope approach implemented …
sensors, is presented. The operating principle is a double slope approach implemented …
A microscale differential capacitive direct wall-shear-stress sensor
V Chandrasekharan, J Sells, J Meloy… - Journal of …, 2011 - ieeexplore.ieee.org
This paper presents the development of a floating-element-based capacitively sensed direct
wall-shear-stress sensor intended for measurements in a turbulent boundary layer. The …
wall-shear-stress sensor intended for measurements in a turbulent boundary layer. The …
A 0.026mm2 capacitance-to-digital converter for biotelemetry applications using a charge redistribution technique
K Tanaka, Y Kuramochi, T Kurashina… - 2007 IEEE Asian …, 2007 - ieeexplore.ieee.org
This paper proposes a direct capacitance-to-digital converter (CDC) for biotelemetry
applications. The proposed circuit is based on a charge redistribution technique using a …
applications. The proposed circuit is based on a charge redistribution technique using a …
[HTML][HTML] Highly Sensitive Capacitive MEMS for Photoacoustic Gas Trace Detection
T Seoudi, J Charensol, W Trzpil, F Pages, D Ayache… - Sensors, 2023 - mdpi.com
An enhanced MEMS capacitive sensor is developed for photoacoustic gas detection. This
work attempts to address the lack of the literature regarding integrated and compact silicon …
work attempts to address the lack of the literature regarding integrated and compact silicon …
Design and implementation of an optimized double closed-loop control system for MEMS vibratory gyroscope
F Chen, W Yuan, H Chang, G Yuan, J Xie… - IEEE Sensors …, 2013 - ieeexplore.ieee.org
This paper describes the development and experimental evaluation of a
microelectromechanical system vibratory gyroscope using an optimized double closed-loop …
microelectromechanical system vibratory gyroscope using an optimized double closed-loop …
Capacitive silicon micro-electromechanical resonator for enhanced photoacoustic spectroscopy
Photoacoustic spectroscopy (PAS) has been increasingly applied to detect gas traces in
many applications. Gas absorption is detected through the excitation of a mechanical …
many applications. Gas absorption is detected through the excitation of a mechanical …
Using dynamic voltage drive in a parallel-plate electrostatic actuator for full-gap travel range and positioning
The nonlinear dynamics of the parallel-plate electrostatically driven microstructure have
been investigated with the objective of finding a dynamic voltage drive suitable for full-gap …
been investigated with the objective of finding a dynamic voltage drive suitable for full-gap …