[HTML][HTML] Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation
One of the critical factors determining the performance of neural interfaces is the electrode
material used to establish electrical communication with the neural tissue, which needs to …
material used to establish electrical communication with the neural tissue, which needs to …
Electrode development for epilepsy diagnosis and treatment
Intracranial recording of human neural activity has been a clinical staple for over 50 years for
a wide range of neuropsychiatric disorders and pathologies. The first intracranial recordings …
a wide range of neuropsychiatric disorders and pathologies. The first intracranial recordings …
Recent advances in clinical electroencephalography
B Frauscher, AO Rossetti… - Current Opinion in …, 2024 - journals.lww.com
Recent advances in clinical electroencephalography : Current Opinion in Neurology Recent
advances in clinical electroencephalography : Current Opinion in Neurology Log in or Register …
advances in clinical electroencephalography : Current Opinion in Neurology Log in or Register …
[HTML][HTML] High-resolution neural recordings improve the accuracy of speech decoding
S Duraivel, S Rahimpour, CH Chiang… - Nature …, 2023 - nature.com
Patients suffering from debilitating neurodegenerative diseases often lose the ability to
communicate, detrimentally affecting their quality of life. One solution to restore …
communicate, detrimentally affecting their quality of life. One solution to restore …
[HTML][HTML] Materials and devices for high-density, high-throughput micro-electrocorticography arrays
The pursuit of precisely recording and localizing neural activities in brain cortical regions
drives the development of advanced electrocorticography (ECoG) devices. Remarkable …
drives the development of advanced electrocorticography (ECoG) devices. Remarkable …
Multiplexed Surface Electrode Arrays Based on Metal Oxide Thin‐Film Electronics for High‐Resolution Cortical Mapping
Electrode grids are used in neuroscience research and clinical practice to record electrical
activity from the surface of the brain. However, existing passive electrocorticography (ECoG) …
activity from the surface of the brain. However, existing passive electrocorticography (ECoG) …
PyHFO: lightweight deep learning-powered end-to-end high-frequency oscillations analysis application
Objective. This study aims to develop and validate an end-to-end software platform, PyHFO,
that streamlines the application of deep learning (DL) methodologies in detecting …
that streamlines the application of deep learning (DL) methodologies in detecting …
Intan Technologies integrated circuits can produce analog-to-digital conversion artifacts that affect neural signal acquisition
K Barth, C Schmitz, T Jochum… - Journal of Neural …, 2024 - iopscience.iop.org
Abstract Objective: Intan Technologies' integrated circuits (ICs) are valuable tools for
neurophysiological data acquisition, providing signal amplification, filtering, and digitization …
neurophysiological data acquisition, providing signal amplification, filtering, and digitization …
Peritumoral cortex: electrophysiological signals
B Díaz-Fernández - 2023 - theses.hal.science
Brain gliomas are highly epileptogenic tumors formed by a macroscopic core and by the
surrounding tissue infiltrated by tumor cells, called the peritumoral tissue. At this level, the …
surrounding tissue infiltrated by tumor cells, called the peritumoral tissue. At this level, the …