Рентгеновские интерферометры Тальбота и Тальбота–Лау
ВВ Лидер - Успехи физических наук, 2023 - mathnet.ru
ВВЛидер, “Рентгеновские интерферометры Тальбота и Тальбота – Лау”, УФН, 193:10 (2023),
1047–1070; Phys. Usp., 66:10 (2023), 987–1007 Успехи физических наук RUS ENG …
1047–1070; Phys. Usp., 66:10 (2023), 987–1007 Успехи физических наук RUS ENG …
Quantitative characterization of ex vivo breast tissue via x-ray phase-contrast tomography
X Li, Z Chen, L Zhang, X Zhu, S Wang… - Journal of X-ray …, 2019 - content.iospress.com
BACKGROUND: Grating-based X-ray phase-contrast imaging (GPCI) has received growing
interests in recent years due to its high capability of visualizing soft tissue. Breast imaging is …
interests in recent years due to its high capability of visualizing soft tissue. Breast imaging is …
Talbot and Talbot–Lau X-ray interferometers
VV Lider - Uspekhi Fizicheskikh Nauk, 2023 - ufn.ru
The operating principles and capabilities of X-ray grating interferometry are described using
Talbot and Talbot±Lau interferometers as examples. Various types of diffraction gratings and …
Talbot and Talbot±Lau interferometers as examples. Various types of diffraction gratings and …
Single-shot X-ray scattering imaging
F Wali, G Kun, W Zhao, Y Lei, J Huang, J Li… - The Imaging Science …, 2020 - Taylor & Francis
In this manuscript, a technique for the fast retrieval and dose saving single-shot imaging of X-
ray scattering information based on angular signal radiography and the staggered grating is …
ray scattering information based on angular signal radiography and the staggered grating is …
Four-dimensional pink-beam x-ray phase tomography for studying laser processing
X-ray phase tomography by Talbot interferometry functions with X-rays of a broad energy
band, and a pink-beam extracted by a multilayer mirror from white synchrotron radiation is …
band, and a pink-beam extracted by a multilayer mirror from white synchrotron radiation is …
Iterative signal retrieval for X-ray grating interferometry with dual-shot
BACKGROUND: X-ray grating interferometry normally requires multiple steps and
exposures, causing a prolonged imaging time. There is motivation to use fewer steps to …
exposures, causing a prolonged imaging time. There is motivation to use fewer steps to …
Absorption imaging performance in a future Talbot-Lau interferometer based breast imaging system
A grating-based x-ray multi-contrast imaging system integrates a source grating G0, a
diffraction grating G1, and an analyzer grating G2 into a conventional x-ray imaging system …
diffraction grating G1, and an analyzer grating G2 into a conventional x-ray imaging system …
Phase-contrast imaging with a compact x-ray light source: system design
X-ray phase-contrast imaging (XPCI) overcomes the problem of low contrast between
different soft tissues achieved in conventional x-ray imaging by introducing x-ray phase as …
different soft tissues achieved in conventional x-ray imaging by introducing x-ray phase as …
Correction of data truncation artifacts in differential phase contrast (DPC) tomosynthesis imaging
The use of grating based Talbot–Lau interferometry permits the acquisition of differential
phase contrast (DPC) imaging with a conventional medical x-ray source and detector …
phase contrast (DPC) imaging with a conventional medical x-ray source and detector …
A single-shot method for X-ray grating interferometry
S Lian, H Kudo - Medical Imaging 2019: Physics of Medical …, 2019 - spiedigitallibrary.org
X-ray phase contrast imaging (PCI) visualizes higher contrast than the conventional
absorption imaging in biological soft tissues. In PCI, the grating-based interferometry has …
absorption imaging in biological soft tissues. In PCI, the grating-based interferometry has …