Assessing the clinical impact of approximations in analytical dose calculations for proton therapy
J Schuemann, D Giantsoudi, C Grassberger… - International Journal of …, 2015 - Elsevier
Purpose To assess the impact of approximations in current analytical dose calculation
methods (ADCs) on tumor control probability (TCP) in proton therapy. Methods Dose …
methods (ADCs) on tumor control probability (TCP) in proton therapy. Methods Dose …
GATE‐RTion: a GATE/Geant4 release for clinical applications in scanned ion beam therapy
L Grevillot, DJ Boersma, H Fuchs… - Medical …, 2020 - Wiley Online Library
Purpose GATE‐RTion is a validated version of GATE for clinical use in the field of light ion
beam therapy. This paper describes the GATE‐RTion project and illustrates its potential …
beam therapy. This paper describes the GATE‐RTion project and illustrates its potential …
Dose to water versus dose to medium in proton beam therapy
H Paganetti - Physics in medicine & biology, 2009 - iopscience.iop.org
Dose in radiation therapy is traditionally reported as the water-equivalent dose, or dose to
water. Monte Carlo dose calculations report dose to medium and thus a methodology is …
water. Monte Carlo dose calculations report dose to medium and thus a methodology is …
Clinical application of in-room positron emission tomography for in vivo treatment monitoring in proton radiation therapy
CH Min, X Zhu, BA Winey, K Grogg, M Testa… - International Journal of …, 2013 - Elsevier
PURPOSE: The purpose of this study is to evaluate the potential of using in-room positron
emission tomography (PET) for treatment verification in proton therapy and for deriving …
emission tomography (PET) for treatment verification in proton therapy and for deriving …
Integration and evaluation of automated Monte Carlo simulations in the clinical practice of scanned proton and carbon ion beam therapy
J Bauer, F Sommerer, A Mairani… - Physics in Medicine …, 2014 - iopscience.iop.org
Monte Carlo (MC) simulations of beam interaction and transport in matter are increasingly
considered as essential tools to support several aspects of radiation therapy. Despite the …
considered as essential tools to support several aspects of radiation therapy. Despite the …
First full-beam PET acquisitions in proton therapy with a modular dual-head dedicated system
During particle therapy irradiation, positron emitters with half-lives ranging from 2 to 20 min
are generated from nuclear processes. The half-lives are such that it is possible either to …
are generated from nuclear processes. The half-lives are such that it is possible either to …
Comparison of Monte Carlo and analytical dose computations for intensity modulated proton therapy
P Yepes, A Adair, D Grosshans… - Physics in Medicine …, 2018 - iopscience.iop.org
To evaluate the effect of approximations in clinical analytical calculations performed by a
treatment planning system (TPS) on dosimetric indices in intensity modulated proton …
treatment planning system (TPS) on dosimetric indices in intensity modulated proton …
Proton and helium ion radiotherapy for meningioma tumors: a Monte Carlo-based treatment planning comparison
T Tessonnier, A Mairani, W Chen, P Sala, F Cerutti… - Radiation …, 2018 - Springer
Background Due to their favorable physical and biological properties, helium ion beams are
increasingly considered a promising alternative to proton beams for radiation therapy …
increasingly considered a promising alternative to proton beams for radiation therapy …
GMC: a GPU implementation of a Monte Carlo dose calculation based on Geant4
L Jahnke, J Fleckenstein, F Wenz… - Physics in Medicine & …, 2012 - iopscience.iop.org
We present a GPU implementation called GMC (GPU Monte Carlo) of the low energy (< 100
GeV) electromagnetic part of the Geant4 Monte Carlo code using the NVIDIA® CUDA …
GeV) electromagnetic part of the Geant4 Monte Carlo code using the NVIDIA® CUDA …
Validation and application of a fast Monte Carlo algorithm for assessing the clinical impact of approximations in analytical dose calculations for pencil beam scanning …
Purpose Monte Carlo (MC) dose calculation is generally superior to analytical dose
calculation (ADC) used in commercial TPS to model the dose distribution especially for …
calculation (ADC) used in commercial TPS to model the dose distribution especially for …