Observer-based pulsed signal injection for grid impedance estimation in three-phase systems

P García, M Sumner… - IEEE Transactions …, 2018 - ieeexplore.ieee.org
This paper addresses the estimation of the grid impedance and the control of grid-tied
converters by combining pulsed signal injection (PSI) and observer-based techniques. A …

Sideband harmonic instability of paralleled inverters with asynchronous carriers

D Yang, X Wang, F Blaabjerg - IEEE Transactions on Power …, 2017 - ieeexplore.ieee.org
Paralleled inverters with asynchronous carriers are increasingly emerging into renewable
power plants and other power-electronic-based power systems. The sideband harmonics …

LCL-resonance damping strategies for grid-connected inverters with LCL filters: a comprehensive review

J Xu, S Xie - Journal of Modern Power Systems and Clean …, 2018 - ieeexplore.ieee.org
Grid-connected LCL-filtered inverters are commonly used for distributed power generators.
The LCL resonance should be treated properly. Recently, many strategies have been used …

On stability of PQ-controlled grid-following and droop-control grid-forming inverters

T Hossen, B Mirafzal - 2022 IEEE Energy Conversion …, 2022 - ieeexplore.ieee.org
This paper demonstrates unexpected instability mode at low power levels. This instability
mode is at low frequencies and can be explained using the root locus of the linearized …

Online monitoring for power cables in DFIG-based wind farms using high-frequency resonance analysis

Y Wu, P Zhang - IEEE Transactions on Sustainable Energy, 2021 - ieeexplore.ieee.org
Increasing demand for renewable energy has led to a rapid growth of doubly fed induction
generator (DFIG)-based wind farms around the world. As a critical component of the DFIG …

Effect of reactive power characteristic of offshore wind power plant on low-frequency stability

W Zhou, Y Wang, RE Torres-Olguin… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
Oscillation phenomena of offshore wind power plant (OWPP) in a wide frequency range can
be caused due to impedance interactions between grid-connected inverters (GCIs) and …

Principle and robust impedance-based design of grid-tied inverter with LLCL-filter under wide variation of grid-reactance

Z Zhang, W Wu, Z Shuai, X Wang, A Luo… - … on Power Electronics, 2018 - ieeexplore.ieee.org
Currently, how the inductive grid impedance variation affects the stability of digitally
controlled grid-tied inverters with a high-order (LCL or LLCL) filter has been numerously …

Robust grid-current-feedback resonance suppression method for LCL-type grid-connected inverter connected to weak grid

X Zhou, L Zhou, Y Chen, Z Shuai… - IEEE Journal of …, 2018 - ieeexplore.ieee.org
In this paper, a robust grid-current-feedback resonance suppression (GCFRS) method for
LCL-type grid-connected inverters is proposed to enhance system damping without …

Internal model-based active resonance damping current control of a grid-connected voltage-sourced converter with an LCL filter

S Leitner, M Yazdanian, S Ziaeinejad… - … on Power Systems, 2018 - ieeexplore.ieee.org
Three-phase passive harmonic filters (eg, LCL filters) are often utilized to attenuate
harmonic currents caused by pulsewidth modulation of voltage-sourced converters (VSC) to …

State space modeling of an offshore wind power plant with an MMC-HVDC connection for an eigenvalue-based stability analysis

GF Gontijo, MK Bakhshizadeh, ŁH Kocewiak… - IEEE …, 2022 - ieeexplore.ieee.org
Large offshore wind power plants (OWPPs) installed far from the coastline are emerging to
benefit from the strong and steady wind resources available at these locations. The high …