Ion-selective membrane electrodes for clinical use.

U Oesch, D Ammann, W Simon - Clinical Chemistry, 1986 - academic.oup.com
We review ion-selective solvent polymeric membrane electrodes for clinical use. The
particular requirements that the clinical application set on the membrane are discussed in …

A comparison of the measurement of sodium and potassium by flame photometry and ion-selective electrode

HGJ Worth - Annals of clinical biochemistry, 1985 - journals.sagepub.com
Although sodium and potassium have been the most commonly assayed analytes by clinical
chemists for many years there have been fewer analytical principles used routinely than for …

Surfactants

RA Llenado, TA Neubecker - Analytical chemistry, 1983 - ACS Publications
This review covers the nominal time period from November 1980 to November 1982. The
clinical chemistry literature is so extensive that we have chosen to review only a portion …

Response of ion-selective field effect transistors to carbon dioxide and organic acids

EJ Fogt, DF Untereker, MS Norenberg… - Analytical …, 1985 - ACS Publications
Sir: In recent years, the fabrication and study of various miniaturized versions of ion-selective
electrodes (ISEs) have been vigorously pursued (1). Once fully developed, it is hoped that …

Determination of sodium and potassium with ion-selective electrodes.

N Fogh-Andersen, PD Wimberley, J Thode… - Clinical …, 1984 - academic.oup.com
We compared different sample-handling techniques for measurement of Na+ and K+ with
ion-selective electrodes (ISE). Imprecision was less for venous blood (with a minimum of …

New in vitro analytical approaches for clinical chemistry measurements in critical care

ME Meyerhoff - Clinical chemistry, 1990 - academic.oup.com
The effective management of patients in intensive care units, operating rooms, and
emergency rooms requires frequent measurement of a select group of analytes, preferably …

Rapid measurement of serum water to assess pseudohyponatremia.

S Faye, RB Payne - Clinical chemistry, 1986 - academic.oup.com
Pseudohyponatremia is caused by an increased serum protein or lipid concentration
producing a" space-occupying lesion" in serum water. Its presence and magnitude must be …

Theory and applications of ion-selective electrodes: Part 6

J Koryta - Analytica chimica acta, 1986 - Elsevier
This review of ion-selective electrodes is arranged in the same way as earlier reviews of this
series. The whole subject continues to grow steadily. Considerable attention has been given …

Electrodes in clinical chemistry

AD Hirst, JF Stevens - Annals of clinical biochemistry, 1985 - journals.sagepub.com
It has been possible to detect salts and bases in solution by electrochemical means for many
years. This technique, which has proved to be particularly useful for the analysis of simple …

Potentiometry of Na+ in undiluted serum and urine with use of an improved neutral carrier-based solvent polymeric membrane electrode.

P Anker, HB Jenny, U Wuthier, R Asper… - Clinical …, 1983 - academic.oup.com
We present an improved Na+-selective liquid membrane electrode for measurement of Na+
concentrations in both undiluted serum and urine. The values for urinary Na+ obtained with …