A review on radiochromic film dosimetry for dose verification in high energy photon beams
T Santos, T Ventura, M do Carmo Lopes - Radiation Physics and Chemistry, 2021 - Elsevier
A dosimetry system composed by Gafchromic™ EBT films and a flatbed document scanner
is a valuable tool for patient-specific quality assurance (QA) of complex external beam …
is a valuable tool for patient-specific quality assurance (QA) of complex external beam …
Evaluation and clinical implementation of in vivo dosimetry for kV radiotherapy using radiochromic film and micro-silica bead thermoluminescent detectors
AL Palmer, SM Jafari, I Mone, S Muscat - Physica Medica, 2017 - Elsevier
Purpose kV radiotherapy treatment calculations are based on flat, homogenous, full-scatter
reference conditions. However, clinical treatments often include surface irregularities and …
reference conditions. However, clinical treatments often include surface irregularities and …
Assessing the deviation from the inverse square law for orthovoltage beams with closed-ended applicators Part II: 30 cm FSD applicators
J Gräfe - Applied Radiation and Isotopes, 2024 - Elsevier
Dose falls-off faster than the inverse square law (ISL) for orthovoltage beams with closed-
ended applicators. This work investigates the discrepancy for 30 cm FSD applicators. When …
ended applicators. This work investigates the discrepancy for 30 cm FSD applicators. When …
Devices for dosimetric measurements and quality assurance of the Xstrahl 300 orthovoltage unit
TY Lim, D Mirkovic, X Wang… - Journal of applied clinical …, 2021 - Wiley Online Library
The Xstrahl 300 orthovoltage unit is designed to deliver kilovoltage radiation therapy using
the appositional technique. However, it is not equipped with some typical linear accelerator …
the appositional technique. However, it is not equipped with some typical linear accelerator …
[HTML][HTML] Determination of Absorbed Dose for Gafchromic EBT3 Film Using Texture Analysis of Scanning Electron Microscopy Images: A Feasibility Study
SY Park - Progress in Medical Physic, 2022 - progmedphys.org
Purpose: We subjected scanning electron microscopic (SEM) images of the active layer of
EBT3 film to texture analysis to determine the dose-response curve. Methods: Uncoated …
EBT3 film to texture analysis to determine the dose-response curve. Methods: Uncoated …
Dosimetric verification and quality assurance for intensity-modulated radiation therapy using Gafchromic® EBT3 film
PurposeThis study aimed to examine the dosimetric properties of Gafchromic® EBT3 film
and intensity-modulated radiation therapy quality assurance (IMRT QA). Materials and …
and intensity-modulated radiation therapy quality assurance (IMRT QA). Materials and …
Dosimetric characterization of a body‐conforming radiochromic sheet
Purpose A novel radiochromic PRESAGE sheet (Heuris Inc.) with 3 mm thickness has been
developed as a measurement tool for 2D dosimetry. Its inherent ability to conform to irregular …
developed as a measurement tool for 2D dosimetry. Its inherent ability to conform to irregular …
[HTML][HTML] The comparison of spatial resolution of ion chamber, diode, and EBT3 film based on the dose profile
HP Hsueh, SA Yeh, L Chang - Therapeutic Radiology and …, 2019 - tro.amegroups.org
Background: It is essential for the physicist to quantify the dose of the radiation prior and
during cancer treatment to ensure proper execution of the treatment plan. The most common …
during cancer treatment to ensure proper execution of the treatment plan. The most common …
Clinical considerations and dosimeters for in vivo dosimetry
D Bollinger, A Darafsheh - Radiation Therapy Dosimetry, 2021 - taylorfrancis.com
In vivo dosimetry is a powerful tool to verify dose delivery accuracy. By placing a radiation
detector at a point of interest, we can validate that the expected dose is delivered to the …
detector at a point of interest, we can validate that the expected dose is delivered to the …
Experiencing In-Vivo Dosimetry Verification in Malaysia: A Patient-Specific EPID-Based Approach
YM Radzi, GH Mohsin, NNN Rizan… - Emerging Advances …, 2024 - publisher.uthm.edu.my
Real-time dosimetry is crucial for patient-specific quality assurance in radiotherapy facilities
across Europe, and the same demand extends to advanced countries like Malaysia. Our …
across Europe, and the same demand extends to advanced countries like Malaysia. Our …