Clinical optical diagnostics–status and perspectives

A Johansson, K Kromer, R Sroka, H Stepp - Medical Laser Application, 2008 - Elsevier
Optical properties of tissue can reveal much more diagnostically relevant information than
has as yet been capitalised on in patients' health care. Only very few optical methods, such …

Resolution in the ApoTome and the confocal laser scanning microscope: comparison

A Weigel, D Schild, A Zeug - Journal of biomedical optics, 2009 - spiedigitallibrary.org
The essential feature of the confocal laser scanning microscope (cLSM) is the generation of
optical sections by the removal of out-of-focus light. About ten years ago, structured …

Dual-modality fluorescence and full-field optical coherence microscopy for biomedical imaging applications

E Auksorius, Y Bromberg, R Motiejūnaitė… - Biomedical optics …, 2012 - opg.optica.org
Full-field optical coherence microscopy (FFOCM) is a high-resolution interferometric
technique that is particularly attractive for biomedical imaging. Here we show that combining …

Fluorescence lifetime imaging in scanning microscopy

HC Gerritsen, A Draaijer, DJ Van den Heuvel… - Handbook of biological …, 2006 - Springer
It was not until the 1930s that measurement of the fluorescence lifetime (τ f) and the
confirmation of theory on this phenomenon became possible (Pringsheim, 1961). Before that …

Photon-counting H33D detector for biological fluorescence imaging

X Michalet, OHW Siegmund, JV Vallerga… - Nuclear Instruments and …, 2006 - Elsevier
We have developed a photon-counting High-temporal and High-spatial resolution, High-
throughput 3-Dimensional detector (H33D) for biological imaging of fluorescent samples …

Inductively coupled pulsed RF voltage multiplier

JM Sanders, M Thomas - US Patent 10,631,395, 2020 - Google Patents
Systems and methods for increasing the RF power switched into a resonant load by
achieving voltage multiplication by means of coupled inductors are provided herein. In one …

Nanosecond pulse generator with a protector circuit

J Sanders, A Kuthi, MA Gundersen… - US Patent 8,120,207, 2012 - Google Patents
This invention relates to a pulse generator circuit for delivering a short high current pulse to
a load. This pulse generator comprises a junction recovery diode, a switch, a first resonant …

Quantitative live cell FLIM imaging in three dimensions

A Le Marois, K Suhling - Multi-Parametric Live Cell Microscopy of 3D …, 2017 - Springer
In this chapter, the concept of fluorescence lifetime and its utility in quantitative live cell
imaging will be introduced, along with methods to record and analyze FLIM data. Relevant …

Fluorescence lifetime system for microscopy and multiwell plate imaging with a blue picosecond diode laser

DS Elson, J Siegel, SED Webb, S Lévêque-Fort… - Optics letters, 2002 - opg.optica.org
We report a wide-field fluorescence lifetime imaging (FLIM) system that uses a blue
picosecond pulsed diode laser as the excitation source. This represents a significant …

Fluorescence lifetime imaging microscopy

A Esposito, FS Wouters - Current Protocols in Cell Biology, 2004 - Wiley Online Library
Fluorescent lifetime imaging microscopy is a powerful tool to enhance the contrast in images
of biological samples and to investigate the local environment of a fluorochrome. FLIM …