CLOTBUST-Hands Free: pilot safety study of a novel operator-independent ultrasound device in patients with acute ischemic stroke

AD Barreto, AV Alexandrov, L Shen, A Sisson… - Stroke, 2013 - Am Heart Assoc
Background and Purpose—The Combined Lysis of Thrombus in Brain Ischemia With
Transcranial Ultrasound and Systemic T-PA-Hands-Free (CLOTBUST-HF) study is a first-in …

Diagnosis and treatment of acute isolated proximal internal carotid artery occlusions: a narrative review

O Kargiotis, K Psychogios, A Safouris… - Therapeutic …, 2022 - journals.sagepub.com
The clinical manifestations of proximal (extracranial) internal carotid artery occlusions
(pICAOs) may range from asymptomatic to acute, large, and devastating ischemic strokes …

Feasibility of Prone Positioning for Brain-injured Patients with Severe Acute Respiratory Distress Syndrome: A Systematic Review and Pilot Study (ProBrain)

Y Elmaleh, A Yavchitz, T Léguillier, PA Squara… - …, 2024 - pubs.asahq.org
Background Prone position is a key component to treat hypoxemia in patients with severe
acute respiratory distress syndrome. However, most studies evaluating it exclude patients …

[HTML][HTML] Vascular imaging in stroke: comparative analysis

K Barlinn, AV Alexandrov - Neurotherapeutics, 2011 - Elsevier
Advances in stroke treatment have mirrored advances in vascular imaging. Understanding
and advances in reperfusion therapies were made possible by improvements in computed …

Imaging of hemorrhagic stroke

R Hakimi, A Garg - CONTINUUM: Lifelong Learning in Neurology, 2016 - journals.lww.com
Abstract Purpose of Review: Hemorrhagic stroke comprises approximately 15% to 20% of all
strokes. This article provides readers with an understanding of the indications and …

Cerebrovascular reactivity impairment in preclinical Alzheimer's disease

M Alwatban, DL Murman… - Journal of Neuroimaging, 2019 - Wiley Online Library
ABSTRACT BACKGROUND AND PURPOSE A substantial overlap exists between declines
in cerebral vasoreactivity (CVR) and symptomatic Alzheimer's disease (AD). CVR can be …

[HTML][HTML] Toward automated classification of pathological transcranial Doppler waveform morphology via spectral clustering

SG Thorpe, CM Thibeault, N Canac, K Jalaleddini… - PloS one, 2020 - journals.plos.org
Cerebral Blood Flow Velocity waveforms acquired via Transcranial Doppler (TCD) can
provide evidence for cerebrovascular occlusion and stenosis. Thrombolysis in Brain …

[HTML][HTML] Doppler and duplex sonography for the diagnosis of the irreversible cessation of brain function (“brain death”): current guidelines in Germany and neighboring …

U Walter, SJ Schreiber, M Kaps - Ultraschall in der Medizin …, 2016 - thieme-connect.com
Extra-and transcranial sonography of brain-supplying arteries is accepted worldwide in
brain death protocols as a valid “ancillary” method of proving brain circulatory arrest. Color …

[HTML][HTML] Reproducibility of Transcranial Doppler ultrasound in the middle cerebral artery

J Kaczynski, R Home, K Shields, M Walters… - Cardiovascular …, 2018 - Springer
Abstract Background Transcranial Doppler ultrasound remains the only imaging modality
that is capable of real-time measurements of blood flow velocity and microembolic signals in …

Real-time validation of transcranial Doppler criteria in assessing recanalization during intra-arterial procedures for acute ischemic stroke an international, multicenter …

G Tsivgoulis, M Ribo, M Rubiera, SN Vasdekis… - Stroke, 2013 - Am Heart Assoc
Background and Purpose—We sought to evaluate the diagnostic accuracy of ultrasound
criteria for recanalization during real-time transcranial Doppler monitoring of intra-arterial …