[HTML][HTML] Development and applications of Compton camera—A review
RK Parajuli, M Sakai, R Parajuli, M Tashiro - Sensors, 2022 - mdpi.com
The history of Compton cameras began with the detection of radiation sources originally for
applications in astronomy. A Compton camera is a promising γ-ray detector that operates in …
applications in astronomy. A Compton camera is a promising γ-ray detector that operates in …
Compton imaging for medical applications
H Tashima, T Yamaya - Radiological Physics and Technology, 2022 - Springer
Compton imaging exploits inelastic scattering, known as Compton scattering, using a
Compton camera consisting of a scatterer detector in the front layer and an absorber …
Compton camera consisting of a scatterer detector in the front layer and an absorber …
[PDF][PDF] Multi-molecule imaging and inter-molecular imaging in nuclear medicine
K Shimazoe, M Uenomachi - Bio-Algorithms and Med-Systems, 2022 - sciendo.com
Multi-molecule imaging and inter-molecular imaging are not fully implemented yet, however,
can become an alternative in nuclear medicine. In this review article, we present arguments …
can become an alternative in nuclear medicine. In this review article, we present arguments …
DOI correction for gamma ray energy reconstruction based on energy segment in 3D position-sensitive CdZnTe detectors
Y Li, P Gong, X Tang, Z Hu, P Wang… - Journal of …, 2022 - iopscience.iop.org
The amplitude of the induced signal in 3D CdZnTe detector depends on the depth of
interaction (DOI). Therefore, calibrating the detector by using DOI correction technology …
interaction (DOI). Therefore, calibrating the detector by using DOI correction technology …
Double photon coincidence crosstalk reduction method for multi-nuclide Compton imaging
M Uenomachi, K Shimazoe… - Journal of …, 2022 - iopscience.iop.org
Compton imaging based on Compton scattering kinematics has the potential to visualize
multi-nuclides by discriminating the total energy of Compton scattering and photoelectric …
multi-nuclides by discriminating the total energy of Compton scattering and photoelectric …
A novel multi-radionuclide imaging method based on mechanical collimated Compton camera
Simultaneous imaging of multiple radionuclides can improve the accuracy of clinical
diagnosis and therapy, and has great significance for clinical and molecular applications …
diagnosis and therapy, and has great significance for clinical and molecular applications …
Compton Imaging Systems Based on Semiconductor Detectors
M Niknami, M Valipour - Gamma Ray Imaging: Technology and …, 2023 - Springer
The Compton imaging system is a technique that uses Compton scattering to produce
images from a gamma-ray source. Compton imaging systems are also known as Compton …
images from a gamma-ray source. Compton imaging systems are also known as Compton …
Development of Compton-PET hybrid imaging system with CeBr3-SiPM arrays
M Uenomachi, K Shimazoe, T Orita… - Journal of …, 2022 - iopscience.iop.org
Positron emission tomography (PET) and single photon emission computed tomography
(SPECT) are both established imaging technologies in nuclear medicine that are clinically …
(SPECT) are both established imaging technologies in nuclear medicine that are clinically …
Influence of spill-over for 99mTc images and the effect of scatter correction for dual-isotope simultaneous acquisition with 99mTc and 18F using small-animal …
T Shibutani, M Onoguchi, T Kanno, S Kinuya - Physical and Engineering …, 2024 - Springer
A dual-isotope simultaneous acquisition (DISA) of 99mTc and 18F affects the image quality
of 99mTc by crosstalk and spill-over from 18F. We demonstrated the influence of spill-over …
of 99mTc by crosstalk and spill-over from 18F. We demonstrated the influence of spill-over …
Dynamic imaging comparison of 18F-FDG tracers with Compton imaging and PET coincidence imaging
D Kim, K Shimazoe, M Uenomachi… - Journal of …, 2022 - iopscience.iop.org
In the clinical situation of positron emission tomography (PET) scans, an activity of an
approximately few hundred megabecquerels (3.7 MBq/kg) is used for injection. Monitoring …
approximately few hundred megabecquerels (3.7 MBq/kg) is used for injection. Monitoring …