[HTML][HTML] Pre-, intra-and post-operative imaging of cochlear implants

TJ Vogl, A Tawfik, A Emam, NNN Naguib… - RöFo-Fortschritte auf …, 2015 - thieme-connect.com
The purpose of this review is to present essential imaging aspects in patients who are
candidates for a possible cochlear implant as well as in postsurgical follow-up. Imaging …

An evidence-based algorithm for intraoperative monitoring during cochlear implantation

MK Cosetti, SH Troob, JM Latzman… - Otology & …, 2012 - journals.lww.com
An Evidence-Based Algorithm for Intraoperative Monitoring Du... : Otology & Neurotology An
Evidence-Based Algorithm for Intraoperative Monitoring During Cochlear Implantation : Otology …

Spread of excitation measurements for the detection of electrode array foldovers: a prospective study comparing 3-dimensional rotational x-ray and intraoperative …

W Grolman, A Maat, F Verdam, Y Simis… - Otology & …, 2009 - journals.lww.com
Objective: The optimal positioning of electrode arrays in the cochlea is extremely important.
Our standard approach is to use a 3-dimensional rotational x-ray for the intraoperative …

The role of post-operative imaging in cochlear implant surgery: a review of 220 adult cases

A Coombs, PJ Clamp, S Armstrong… - Cochlear Implants …, 2014 - Taylor & Francis
Objectives To determine the incidence of abnormal radiological findings after cochlear
implantation and their effect on clinical outcomes. Methods Retrospective review of 220 …

Prevalence of extracochlear electrodes: computerized tomography scans, cochlear implant maps, and operative reports

JT Holder, DM Kessler, JH Noble, RH Gifford… - Otology & …, 2018 - journals.lww.com
Objective: To quantify and compare the number of cochlear implant (CI) electrodes found to
be extracochlear on postoperative computerized tomography (CT) scans, the number of …

[HTML][HTML] Application of intentional facial nerve stimulation during cochlear implantation as an electrophysiological tool to estimate the intracochlear electrode position

DP Herrmann, FT Müller-Graff, S Kaulitz, M Cebulla… - Scientific Reports, 2022 - nature.com
This proof of concept describes the use of evoked electromyographic (EMG) activation of the
facial nerve for intraoperative monitoring of the electrode insertion during cochlear …

Intraoperative electrophysiologic variations caused by the scalar position of cochlear implant electrodes

P Mittmann, A Ernst, I Todt - Otology & Neurotology, 2015 - journals.lww.com
Objective The position of cochlear implant (CI) electrodes in the cochlea is fundamental for
the interaction between the implant and the neurons of the spiral ganglion. The scalar …

Artifacts of the electrode in cochlea implantation and limits in analysis of deep insertion in cone beam tomography (CBT)

C Güldner, S Wiegand, R Weiss, S Bien… - European Archives of …, 2012 - Springer
Until now more than 250,000 cochlea implantations have been performed worldwide. The
surgical procedure is well standardized. A discussion about the kind of postoperative …

Electrophysiological detection of electrode fold-over in perimodiolar cochlear implant electrode arrays: a multi-center study case series

P Mittmann, G Lauer, A Ernst, S Mutze… - European Archives of …, 2020 - Springer
Purpose It is important for the surgeon to determine the position of the CI electrode array
during and after its placement within the cochlea. Most preferably, this should be within the …

Real-time intraoperative computed tomography to assist cochlear implant placement in the malformed inner ear

JD Bloom, MD Rizzi, JA Germiller - Otology & Neurotology, 2009 - journals.lww.com
Objective: Cochlear implantation is increasingly being performed in children with inner ear
malformations. In severe cochleovestibular anomalies, such as severe partitioning defects …