Towards geometrical calibration of x-ray computed tomography systems—a review

M Ferrucci, RK Leach, C Giusca… - Measurement …, 2015 - iopscience.iop.org
Industrial x-ray computed tomography (XCT) is seen as a potentially effective tool for the
industrial inspection of complex parts. In particular, XCT is an attractive solution for the …

Rigid motion compensation in interventional C-arm CT using consistency measure on projection data

R Frysch, G Rose - Medical Image Computing and Computer-Assisted …, 2015 - Springer
Interventional C-arm CT has the potential to visualize brain hemorrhages in the operating
suite and save valuable time for stroke patients. Due to the critical constitution of the …

Calibration for circular cone-beam CT based on consistency conditions

J Lesaint, S Rit, R Clackdoyle… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
In cone-beam computed tomography (CT), imprecise knowledge of the acquisition geometry
can severely impact the quality of the reconstructed image. This paper investigates …

X-ray posenet: 6 dof pose estimation for mobile x-ray devices

M Bui, S Albarqouni, M Schrapp… - 2017 IEEE Winter …, 2017 - ieeexplore.ieee.org
Precise reconstruction of 3D volumes from X-ray projections requires precisely pre-
calibrated systems where accurate knowledge of the systems geometric parameters is …

Data consistency conditions in X-ray transmission imaging and their application to the self-calibration problem.

J Lesaint - 2018 - theses.hal.science
In X-ray transmission imaging, the collected measurements correspond to an integral
operator: the Radon transform in parallel geometry and the divergent beam transform in …

Tomosynthesis implementation with adaptive online calibration on clinical c-arm systems

K Chung, LR Schad, FG Zöllner - International journal of computer assisted …, 2018 - Springer
Purpose Cone beam computed tomography (CBCT) systems offer physicians crucial 3D and
2D imaging capabilities during interventions. However, certain medical applications only …

Feature-based CBCT self-calibration for arbitrary trajectories

C Tönnes, T Russ, LR Schad, FG Zöllner - International Journal of …, 2022 - Springer
Purpose Development of an algorithm to self-calibrate arbitrary CBCT trajectories which can
be used to reduce metal artifacts. By using feature detection and matching we want to …

Data sustained misalignment correction in microscopic cone beam CT via optimization under the Grangeat Epipolar consistency condition

S Luo, L Zheng, S Luo, N Gu, X Tang - Medical physics, 2020 - Wiley Online Library
Purpose The misalignment correction in cone beam computed tomography (CBCT), which is
usually carried out in an offline manner, is a difficult and tedious process. It becomes even …

Feature-Oriented CBCT Self-Calibration Parameter Estimator for Arbitrary Trajectories: FORCAST-EST

C Tönnes, FG Zöllner - Applied Sciences, 2023 - mdpi.com
Background: For the reconstruction of Cone-Beam CT volumes, the exact position of each
projection is needed; however, in some situations, this information is missing. Purpose: The …

基于稀疏随机投影的SIFT 医学图像配准算法

杨飒, 郑志硕 - 量子电子学报, 2015 - lk.hfcas.ac.cn
针对尺度不变特征变换(Scale-Invariant Feature Transform, SIFT) 算法在关键点特征描述向量
阶段计算复杂并且维数较高的现象, 提出了一种基于压缩感知理论的SIFT 算法 …