New generation non-stationary portable neutron generators for biophysical applications of Neutron Activation Analysis

N Marchese, A Cannuli, MT Caccamo… - Biochimica et Biophysica …, 2017 - Elsevier
Background Neutron sources are increasingly employed in a wide range of research fields.
For some specific purposes an alternative to existing large-scale neutron scattering facilities …

Contraband detection with fast neutrons

A Buffler - Radiation Physics and Chemistry, 2004 - Elsevier
Recent terror events and the increase in the trade of illicit drugs have fuelled the exploration
of the use of fast neutrons as probes for the detection of hidden contraband, especially …

Measuring the Migdal effect in semiconductors for dark matter detection

D Adams, D Baxter, H Day, R Essig, Y Kahn - Physical Review D, 2023 - APS
The Migdal effect has received much attention from the dark matter direct detection
community, in particular due to its power in setting leading limits on sub-GeV particle dark …

Response of CsI [Na] to nuclear recoils: Impact on coherent elastic neutrino-nucleus scattering

JI Collar, ARL Kavner, CM Lewis - Physical Review D, 2019 - APS
A new measurement of the quenching factor for low-energy nuclear recoils in CsI [Na] is
presented. Past measurements are revisited, identifying and correcting several systematic …

[图书][B] 14 MeV neutrons: physics and applications

V Valkovic - 2015 - books.google.com
This book reflects developments in both fundamental nuclear physics and the application of
fast neutrons to many practical problems in medicine, the environment, security, and other …

New measurement of the scintillation efficiency of low-energy nuclear recoils in liquid xenon

G Plante, E Aprile, R Budnik, B Choi, KL Giboni… - Physical Review C …, 2011 - APS
Particle detectors that use liquid xenon (LXe) as detection medium are among the leading
technologies in the search for dark matter weakly interacting massive particles (WIMPs). A …

Quenching and channeling of nuclear recoils in NaI (Tl): Implications for dark-matter searches

JI Collar - Physical Review C—Nuclear Physics, 2013 - APS
A new experimental evaluation of the quenching factor for nuclear recoils in NaI [Tl] is
described. Systematics affecting previous measurements are addressed by careful …

Application of deuteron–deuteron (D–D) fusion neutrons to 40Ar/39Ar geochronology

PR Renne, KB Knight, S Nomade, KN Leung… - Applied Radiation and …, 2005 - Elsevier
Neutron irradiation of samples for 40Ar/39Ar dating in a 235U fission reactor requires error-
producing corrections for the argon isotopes created from Ca, K, and, to a lesser extent, Cl …

Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using DD neutron scattering kinematics

DS Akerib, S Alsum, HM Araújo, X Bai… - arXiv preprint arXiv …, 2016 - arxiv.org
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time
projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead …

Advanced compact accelerator neutron generator technology for active neutron interrogation field work

DL Chichester, JD Simpson, M Lemchak - Journal of Radioanalytical and …, 2007 - Springer
Due to a need for security screening instruments capable of detecting explosives and
nuclear materials there is growing interest in neutron generator systems suitable for field use …