Principles of pulse oximetry: theoretical and practical considerations
CM Alexander, LE Teller, JB Gross - Anesthesia & Analgesia, 1989 - journals.lww.com
In addition to absorption by hemoglobin, refraction and reflection (ie, scattering) of the light
beam also occur within tissue beds. Scattering at the interface of red cells and plasma may …
beam also occur within tissue beds. Scattering at the interface of red cells and plasma may …
[HTML][HTML] A systematic review of nutrition recommendation systems: with focus on technical aspects
Background: Nutrition informatics has become a novel approach for registered dietitians to
practice in this field and make a profit for health care. Recommendation systems considered …
practice in this field and make a profit for health care. Recommendation systems considered …
Photoplethysmograph fingernail sensors for measuring finger forces without haptic obstruction
SA Mascaro, HH Asada - IEEE Transactions on robotics and …, 2001 - ieeexplore.ieee.org
A new type of touch sensor for detecting contact pressure at human fingertips is presented.
This new sensor allows the fingers to directly contact the environment without obstructing the …
This new sensor allows the fingers to directly contact the environment without obstructing the …
[图书][B] The development of a near infrared spectroscopy system and its application for non invasive monitoring of cerebral blood and tissue oxygenation in the …
M Cope - 1991 - search.proquest.com
This project had two main objectives. The first of these was to design and construct a
spectroscopic instrument to monitor small changes in optical transmission across an infant's …
spectroscopic instrument to monitor small changes in optical transmission across an infant's …
[PDF][PDF] The application of near infrared spectroscopy to non invasive monitoring of cerebral oxygenation in the newborn infant
M Cope - Department of Medical Physics and Bioengineering, 1991 - Citeseer
This project had two main objectives. The first of these was to design and construct a
spectroscopic instrument to monitor small changes in optical transmission across an infant's …
spectroscopic instrument to monitor small changes in optical transmission across an infant's …
Pulse oximeter with calibration stabilization
JL Reuss - US Patent 6,711,425, 2004 - Google Patents
An improved pulse oximeter (sensor and monitor) uses a plurality of wavelengths selected to
provide sensitivity to both oxygen saturation and deviations in tissue site characteristic (s) …
provide sensitivity to both oxygen saturation and deviations in tissue site characteristic (s) …
Light-scattering technique for the study of orientation and deformation of red blood cells in a concentrated suspension
AH Gandjbakhche, P Mills, P Snabre - Applied Optics, 1994 - opg.optica.org
The backscattered and transmitted diagrams of He–Ne laser light illuminating a
concentrated suspension of red blood cells (RBC's) are investigated. The shapes of these …
concentrated suspension of red blood cells (RBC's) are investigated. The shapes of these …
Diffusion model of the optical absorbance of whole blood
JM Steinke, AP Shepherd - JOSA A, 1988 - opg.optica.org
Photon-diffusion theory has had limited success in modeling the optical transmittance of
whole blood. Therefore we have developed a new photon-diffusion model of the optical …
whole blood. Therefore we have developed a new photon-diffusion model of the optical …
Method and apparatus for noninvasively monitoring hemoglobin concentration and oxygen saturation
K Jeon, G Yoon - US Patent 6,714,805, 2004 - Google Patents
A method and apparatus for noninvasively monitoring hemoglobin concentration and
oxygen saturation, wherein the method includes selecting at least two wavelengths from a …
oxygen saturation, wherein the method includes selecting at least two wavelengths from a …
Reflectance pulse oximetry–principles and obstetric application in the Zurich system
V König, R Huch, A Huch - Journal of Clinical Monitoring and Computing, 1998 - Springer
Transmission and reflectance are the two main modes of pulse oximetry. In obstetrics, due to
the absence of a transilluminable fetal part for transmission oximetry, the only feasible option …
the absence of a transilluminable fetal part for transmission oximetry, the only feasible option …