Passivity Enhancement for LCL-Filtered Inverter With Grid Current Control and Capacitor Current Active Damping
This article takes a deep insight into the passivity-based design of LCL-filtered inverter with
grid current control and capacitor current active damping. It reveals that although an optimal …
grid current control and capacitor current active damping. It reveals that although an optimal …
Passivity-based design of plug-and-play current-controlled grid-connected inverters
A Akhavan, HR Mohammadi… - … on Power Electronics, 2019 - ieeexplore.ieee.org
Stable operation of LCL filtered grid-connected inverters can be achieved using active
damping. However, the stability can be threatened by non-ideal conditions such as delay in …
damping. However, the stability can be threatened by non-ideal conditions such as delay in …
Comprehensive modeling, analysis, and comparison of state-space and admittance models of PLL-based grid-following inverters considering different outer control …
The phase-locked loop (PLL)-based grid-following inverters have been widely used as the
interface between renewable energy resources (eg, wind and solar power) and the utility …
interface between renewable energy resources (eg, wind and solar power) and the utility …
Design of PWM-SMC Controller Using Linearized Model for Grid-Connected Inverter With LCL Filter
Nowadays, various sliding-mode control (SMC) methods have been successfully applied to
the digitally controlled grid-connected inverter (GCI) with an LCL filter. However, how to …
the digitally controlled grid-connected inverter (GCI) with an LCL filter. However, how to …
Optimal LCL-filter design method for grid-connected renewable energy sources
C Gurrola-Corral, J Segundo, M Esparza… - International Journal of …, 2020 - Elsevier
This paper presents a design method based on the extended harmonic domain modeling for
L and LCL passive filters of active-front-end PWM two-level voltage source converters for …
L and LCL passive filters of active-front-end PWM two-level voltage source converters for …
Robust optimized current controller based on a two-step procedure for grid-connected converters
Proportional-resonant controllers are largely used for grid-connected converters with LCL
filters to ensure sinusoidal reference tracking and harmonic disturbance rejection. However …
filters to ensure sinusoidal reference tracking and harmonic disturbance rejection. However …
Robust Control Parameters Design of PBC Controller for LCL-Filtered Grid-Tied Inverter
J Zhao, W Wu, Z Shuai, A Luo… - … on Power Electronics, 2019 - ieeexplore.ieee.org
Owing to the strong robustness against system parameter changes and external
perturbations, the passivity-based control (PBC) has been widely adopted in grid-tied …
perturbations, the passivity-based control (PBC) has been widely adopted in grid-tied …
Stability region exploring of shunt active power filters based on output admittance modeling
A shunt active power filter (SAPF) is coupled with load admittance in weak grid conditions,
which poses a challenge to stability analysis. In this article, the admittance model of the …
which poses a challenge to stability analysis. In this article, the admittance model of the …
Robust Control of GTIs under wide grid impedance ranges: An approach combining metaheuristics and LMIs
This paper provides a new design procedure for robust state feedback current controllers
suitable for grid-tied inverters under wide grid impedance ranges. The proposed procedure …
suitable for grid-tied inverters under wide grid impedance ranges. The proposed procedure …
Impedance-based analysis of digital control delay in grid-tied voltage source inverters
Digital control delay is studied as one of the leading factors causing instability in grid-tied
voltage source inverter (VSI) systems. However, how this delay affects the small-signal …
voltage source inverter (VSI) systems. However, how this delay affects the small-signal …