[HTML][HTML] Joint recommendations for reporting carotid ultrasound investigations in the United Kingdom
CP Oates, AR Naylor, T Hartshorne, SM Charles… - European Journal of …, 2009 - Elsevier
At present in the United Kingdom a number of different criteria are used to grade disease in
carotid ultrasound investigations. One main cause of this has been the difference in the …
carotid ultrasound investigations. One main cause of this has been the difference in the …
[HTML][HTML] Altered Doppler flow patterns in cirrhosis patients: an overview
Doppler ultrasonography of the hepatic vasculature is an integral part of evaluating
precirrhotic and cirrhotic patients. While the reversal of the portal venous flow is a well …
precirrhotic and cirrhotic patients. While the reversal of the portal venous flow is a well …
Progression rate and ipsilateral neurological events in asymptomatic carotid stenosis
LS Hirt - Stroke, 2014 - Am Heart Assoc
Background and Purpose—Progression of asymptomatic carotid stenoses with> 50%
luminal narrowing is associated with an increased risk of stroke. The significance of the …
luminal narrowing is associated with an increased risk of stroke. The significance of the …
Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements
Background Non-invasive measures that can accurately estimate cardiac output may help
identify volume-responsive patients. This study seeks to compare two non-invasive …
identify volume-responsive patients. This study seeks to compare two non-invasive …
[HTML][HTML] Why are we still debating criteria for carotid artery stenosis?
The risk of new or recurrent stroke is high among patients with extracranial carotid artery
stenosis and the benefit of carotid revascularization is associated to the degree of luminal …
stenosis and the benefit of carotid revascularization is associated to the degree of luminal …
Estimation of blood velocity, volumetric flow and wall shear rate using Doppler ultrasound
PR Hoskins - Ultrasound, 2011 - journals.sagepub.com
Commercial ultrasound systems can make a number of measurements related to
haemodynamics which are relevant to clinical practice and to clinical research. These …
haemodynamics which are relevant to clinical practice and to clinical research. These …
Ultrasound diagnosis of carotid artery stenosis and occlusion
H Takekawa, D Tsukui, S Kobayasi, K Suzuki… - Journal of Medical …, 2022 - Springer
Carotid artery ultrasonography is capable of diagnosing or inferring the presence or
absence of stenosis or occlusion of the internal carotid artery (ICA) and vertebral artery (VA) …
absence of stenosis or occlusion of the internal carotid artery (ICA) and vertebral artery (VA) …
Comparison of the carotid corrected flow time and tidal volume challenge for assessing fluid responsiveness in robot-assisted laparoscopic surgery
X Tang, Q Chen, Z Huang, J Liang, R An… - Journal of Robotic Surgery, 2023 - Springer
We aimed to compare the ability of carotid corrected flow time assessed by ultrasound and
the changes in dynamic preload indices induced by tidal volume challenge predicting fluid …
the changes in dynamic preload indices induced by tidal volume challenge predicting fluid …
Haemodynamics and blood flow measured using ultrasound imaging
PR Hoskins - Proceedings of the Institution of Mechanical …, 2010 - journals.sagepub.com
Visualization of, and measurements related to, haemodynamic phenomena in arteries may
be made using ultrasound systems. Most ultrasound technology relies on simple …
be made using ultrasound systems. Most ultrasound technology relies on simple …
Smartphone-based point-of-care system using continuous-wave portable Doppler
Point-of-care Ultrasound (PoCUS) is a safe, repeatable, and inexpensive bedside diagnostic
tool. Over the years, PoCUS services are adopted in resource-limited settings for faster and …
tool. Over the years, PoCUS services are adopted in resource-limited settings for faster and …