[HTML][HTML] Joint recommendations for reporting carotid ultrasound investigations in the United Kingdom

CP Oates, AR Naylor, T Hartshorne, SM Charles… - European Journal of …, 2009 - Elsevier
At present in the United Kingdom a number of different criteria are used to grade disease in
carotid ultrasound investigations. One main cause of this has been the difference in the …

[HTML][HTML] Altered Doppler flow patterns in cirrhosis patients: an overview

P Iranpour, C Lall, R Houshyar, M Helmy, A Yang… - …, 2016 - ncbi.nlm.nih.gov
Doppler ultrasonography of the hepatic vasculature is an integral part of evaluating
precirrhotic and cirrhotic patients. While the reversal of the portal venous flow is a well …

Progression rate and ipsilateral neurological events in asymptomatic carotid stenosis

LS Hirt - Stroke, 2014 - Am Heart Assoc
Background and Purpose—Progression of asymptomatic carotid stenoses with> 50%
luminal narrowing is associated with an increased risk of stroke. The significance of the …

Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements

IWY Ma, JD Caplin, A Azad, C Wilson, MA Fifer… - Critical ultrasound …, 2017 - Springer
Background Non-invasive measures that can accurately estimate cardiac output may help
identify volume-responsive patients. This study seeks to compare two non-invasive …

[HTML][HTML] Why are we still debating criteria for carotid artery stenosis?

VJ Del Brutto, HL Gornik, T Rundek - Annals of translational …, 2020 - ncbi.nlm.nih.gov
The risk of new or recurrent stroke is high among patients with extracranial carotid artery
stenosis and the benefit of carotid revascularization is associated to the degree of luminal …

Estimation of blood velocity, volumetric flow and wall shear rate using Doppler ultrasound

PR Hoskins - Ultrasound, 2011 - journals.sagepub.com
Commercial ultrasound systems can make a number of measurements related to
haemodynamics which are relevant to clinical practice and to clinical research. These …

Ultrasound diagnosis of carotid artery stenosis and occlusion

H Takekawa, D Tsukui, S Kobayasi, K Suzuki… - Journal of Medical …, 2022 - Springer
Carotid artery ultrasonography is capable of diagnosing or inferring the presence or
absence of stenosis or occlusion of the internal carotid artery (ICA) and vertebral artery (VA) …

Comparison of the carotid corrected flow time and tidal volume challenge for assessing fluid responsiveness in robot-assisted laparoscopic surgery

X Tang, Q Chen, Z Huang, J Liang, R An… - Journal of Robotic Surgery, 2023 - Springer
We aimed to compare the ability of carotid corrected flow time assessed by ultrasound and
the changes in dynamic preload indices induced by tidal volume challenge predicting fluid …

Haemodynamics and blood flow measured using ultrasound imaging

PR Hoskins - Proceedings of the Institution of Mechanical …, 2010 - journals.sagepub.com
Visualization of, and measurements related to, haemodynamic phenomena in arteries may
be made using ultrasound systems. Most ultrasound technology relies on simple …

Smartphone-based point-of-care system using continuous-wave portable Doppler

B Jana, R Biswas, PK Nath, G Saha… - IEEE Transactions on …, 2020 - ieeexplore.ieee.org
Point-of-care Ultrasound (PoCUS) is a safe, repeatable, and inexpensive bedside diagnostic
tool. Over the years, PoCUS services are adopted in resource-limited settings for faster and …